VDF730
User
Manual
Desc
ription
of
Function
Codes
-
113
-
precedence
over
function
31
(
Command
source
switchover
to
terminal
control
).
When
either
of
the
two
functions
is
valid
,
the
function
of
switchover
between
operation
panel
control
and
remote
command
channel
provided
by
the
MF
.
K
key is disabled.
•
Motor
2
parameters
are
set
in group FC
;
the V
/
F
curve
of motor
2
is
straight
line by
default
;
the
acceleration
/
deceleration
time
is
set
in
FC
-
09
.
The three multi
-
reference terminals have 16 state combinations
,
corresponding to eight
reference
values
,
as
listed
in
the
following
table
.
Table
6
-
3
State
combinations
of
the
four
multi
-
reference
terminals
K3
K2
K1
Reference Setting
Corresponding
Parameter
OFF
OFF
OFF
Reference
0
P8
-
00
OFF
OFF
ON
Reference
1
P8
-
01
OFF
ON
OFF
Reference
2
P8
-
02
OFF
ON
ON
Reference
3
P8
-
03
ON
OFF
OFF
Reference
4
P8
-
04
ON
OFF
ON
Reference
5
P8
-
05
ON
ON
OFF
Reference
6
P8
-
06
ON
ON
ON
Reference
7
P8
-
07
Function
Code
Parameter
Name
Setting
Range
Default
P2
-
05
DI
flter
time
0
–
10
4
It is used to set the software filter time of DI terminal status
.
If DI terminals are liable to
interference and
may
cause
malfunction
,
increase
the
value
of
this parameter to enhance
the
anti
-
interference
capability
.
However
,
increase
of
DI
flter
time
will
reduce
the
response
of
DI
terminals
.
Function
Code
Parameter
Name
Setting
Range
Default
P2
-
06
Terminal
command
mode
0
:
Two
-
line
mode
1
1
:
Two
-
line
mode
2
2
:
Three
-
line
mode
1
3
:
Three
-
line
mode
2
0
This parameter is used to set the mode in which the AC drive is controlled by external
terminals
.
The following uses DI1
,
DI2 and DI3 among DI1 to DI5 as an example
,
with
allocating
functions
of
DI1
,
DI2
and
DI3
by
setting
P2
-
00
to
P4
-
02
.
•
0
:
Two
-
line
mode
1
It
is
the
most
commonly
used two
-
line mode
,
in
which
the
forward
/
reverse rotation of
the
motor
is
decided
by
DI1
and
DI2
.
The
parameters
are
set
as
below
:
Function
Code
Parameter
Name
Value
Function
Description
P2
-
06
Terminal
command
mode
0
Two
-
line
1
P2
-
00
DI1
function
selection
1
Forward
RUN
(
FWD
)
P2
-
01
DI2
function
selection
2
Reverse
RUN
(
REV
)
Содержание VDF730 Series
Страница 1: ...VDF730 Series...
Страница 7: ......
Страница 8: ...1 Safety Information and Precautions...
Страница 15: ...Safety Information and Precautions VDF730 User Manual 14...
Страница 16: ...2 Product Information...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Страница 52: ...4 Operation and Display...
Страница 75: ...Operation and Display VDF730 User Manual 74...
Страница 76: ...5 Function Code Table...
Страница 97: ...Function Code Table VDF730 User Manual 96...
Страница 98: ...6 Description of Function Codes...
Страница 153: ...Description of Function Codes VDF730 User Manual 152...
Страница 154: ...7 EMC...
Страница 158: ...8 Troubleshooting...
Страница 165: ...Troubleshooting VDF730 User Manual 164...