VDF730
User
Manual
Operation
and
Display
-
67
-
Figure
4
-
24
Reversing
the
motor
rotating
direction
Command
source
(
operation
panel control
)
Forward
rotation
command
(
terminal
,
communication
)
Reverse
rotation
command
(
terminal
,
communication
)
Fs
>
0
Fs
≤
0
Fs
≤
0
Fs
>
0
P0
-
12
0
0
1
1
0
1
P5
-
09
Set
frequency
Rotating
direction
setting
Reverse
control
enabled
Forward
rotation
Reverse
rotation
Rotating
at 0
.
0
Hz
According to the preceding figure
,
when the running frequency of the AC drive is set by
means of communication
(
P0
-
01
=
8
)
and reverse control is enabled
(
P5
-
09
=
0
),
the AC
drive
instructs
the
reverse
direction
if
the
set
frequency
Fs
is
a
negative
value
.
If
the
give
running
command
is
reverse
rotation
or
the
set
frequency
is
a
negative
value
,
but
reverse
control
is
disabled
(
P5
-
09
=
1
),
the
AC
drive
will
run
at
0
Hz
and
has
no
output
.
In some applications where reverse rotation is prohibited
,
do not change the rotating
direction
by
modifying
the
function
codes
because
the
function
codes
will
be
restored
once
the
AC
drive
restores
the
default
settings
.
4
.
6
.
9
Setting
the
Fixed
Length
Control
Mode
The
VDF730
has
the
fxed
length
control
function
.
The
length
pulses
are
sampled
by
the
DI
allocated
with
function
25
(
Length
count
input
).
The
"
Actual
length
" (
P7
-
06
)
is
obtained
by
dividing
the
number
of
pulses
sampled
by
the
value
of
P7
-
07
(
Number
of
pulses
per
meter
).
If the
actual
length is larger
than the
"
Set
length
" (
P7
-
05
),
the multifunctional DO
terminal
becomes
ON
.
In
the
process
of
fxed
length
control
,
the
length
can
be
reset
by
means
of
the
DI
terminal
allocated
with
function
26
(
Length
reset
).
The
related
setting
is
shown
in
the
following
fgure
.
Figure
4
-
25
Function
code
setting
for
fxed
length
control
P2
-
04
=
25
(
Length pulses
input
)
DI5
P2
-
00 to P2
-
24
=
26
(
Length reset
)
P7
-
07
(
Number of
pulses per
meter
)
Length pulses
Length reset
P7
-
06
(
Actual length
)
P7
-
05
(
Set length
)
≥
P3
-
01 to P3
-
04
=
12
(
Length reached
)
Reset
Clear to
0
÷
After the
length is
reached
,
the DO
becomes 1
.
Length reset input
Length reached output
Length pulses input
1 2 3
10 11 12
1 2
P7
-
06
=
0
P7
-
06
=
11
P7
-
05
=
11
U0
-
13
(
Length value
)
Содержание VDF730 Series
Страница 1: ...VDF730 Series...
Страница 7: ......
Страница 8: ...1 Safety Information and Precautions...
Страница 15: ...Safety Information and Precautions VDF730 User Manual 14...
Страница 16: ...2 Product Information...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Страница 52: ...4 Operation and Display...
Страница 75: ...Operation and Display VDF730 User Manual 74...
Страница 76: ...5 Function Code Table...
Страница 97: ...Function Code Table VDF730 User Manual 96...
Страница 98: ...6 Description of Function Codes...
Страница 153: ...Description of Function Codes VDF730 User Manual 152...
Страница 154: ...7 EMC...
Страница 158: ...8 Troubleshooting...
Страница 165: ...Troubleshooting VDF730 User Manual 164...