VDF730
User
Manual
Desc
ription
of
Function
Codes
-
133
-
When the dormant function is enabled
,
if the frequency source is PID
,
whether PID
operation
is
performed
in
the
dormant
state
is
determined
by
P6
-
10
.
In
this
case
,
select
PID
operation
enabled
in
the
stop
state
(
P6
-
10
=
1
).
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
25
Software
overcurrent
threshold
0
.
0
%–
300
.
0
% (
rated
motor
current
)
200
.
0
%
P5
-
26
Software
overcurrent
detection
delay
0
.
00s
(
no
detection
)
0
.
01
–
6500
.
0s
0
.
0s
If the output current of the AC drive reaches the overcurrent threshold and the duration
exceeds
the
detection
delay
time
,
the
AC
drive
reports
ERR31
.
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
27
Overcurrent
detection
delay
(
for
DO
output
)
0
.
00s
(
no
detection
)
0
.
01
–
6500
.
0s
0
.
00s
If the output current of the AC drive reaches the overcurrent threshold and the duration
exceeds
the
detection
delay
time
,
the
DO
terminal
with
function
20
becomes
ON
.
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
37
Dead
zone
compensation
0
:
Disabled
1
:
Enabled
1
If
the
frequency
is
lower
than
200
Hz
,
set
this
parameter
to
0
;
otherwise
,
set
this
parameter
to
1
.
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
38
Cooling
fan
control
0
:
Fan
working
during
running
1
:
Fan
working
continuously
after
power
-
on
0
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
39
External
braking
startup
frequency
0
.
00
Hz
to
maximum
frequency
(
P0
-
04
)
0
.
00
Hz
P5
-
40
External
braking
time
0
.
0
–
3600
.
0s
0
.
0s
At
stop
,
when
the
running
frequency
is
lower
than
the
value
of
P5
-
39
,
the
braking
signal
is
active
.
The
braking
signal
becomes
invalid
after
lasting
the
time
set
in
P5
-
40
.
The
braking
signal
is
inactive
during
startup
.
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
41
Jump
frequency
execution
mode
0
:
Not
execute
during
acceleration
/
deceleration
1
:
Execute
during
acceleration
/
deceleration
0
Function
Code
Parameter
Name
Setting
Range
Default
P5
-
43
Power
-
on
time
(
in
second
)
0
.
00
–
3599s
0s
Содержание VDF730 Series
Страница 1: ...VDF730 Series...
Страница 7: ......
Страница 8: ...1 Safety Information and Precautions...
Страница 15: ...Safety Information and Precautions VDF730 User Manual 14...
Страница 16: ...2 Product Information...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Страница 52: ...4 Operation and Display...
Страница 75: ...Operation and Display VDF730 User Manual 74...
Страница 76: ...5 Function Code Table...
Страница 97: ...Function Code Table VDF730 User Manual 96...
Страница 98: ...6 Description of Function Codes...
Страница 153: ...Description of Function Codes VDF730 User Manual 152...
Страница 154: ...7 EMC...
Страница 158: ...8 Troubleshooting...
Страница 165: ...Troubleshooting VDF730 User Manual 164...