Description
of
Function
Codes
VDF730
User
Manual
-
112
-
Value
Function
Description
27
Exchange
of
AI1
and
AI2
settings
When
this
terminal
becomes
ON
,
the
setting
values
of
AI1
and
AI2
are
exchanged
,
but
the
corresponding
setting
of
AI1
maximum
input
(
P2
-
11
)
and
the
corresponding
setting
of
AI2
maximum
input
(
P2
-
17
)
remain
unchanged
.
28
Frequency
source
switched
over
to
AI1
When
this
terminal
becomes
ON
,
the
current
frequency
source
is
switched
over
to
AI1
setting
.
This
function
is
valid
only
when
P0
-
18
is
set
to
0
.
29
DC
braking
at
stop
enabled
When
this
terminal
is
ON
,
the
AC
drive
performs
DC
braking
to
stop
based
on
the
initial
frequency
,
waiting
time
,
braking
current
,
and
braking
time
set
in
P4
-
11
to
P4
-
14
.
This
function
is
valid
by
default
.
30
Command
source
switchover
to
operation
panel
control
When
this
terminal
is
ON
,
the
current
command
source
is
switched
over
to
"
operation
panel
control
".
31
Command
source
switchover
to
terminal
control
When
this
terminal
is
ON
,
the
current
command
source
is
switched
over
to
"
terminal
control
".
32
Motor
switchover
When
this
terminal
becomes
ON
,
motor
1
is
switched
over
to
motor
2
.
This
function
is
valid
only
at
stop
,
and
the
AC
drive
reports
Err41
when
you
perform
switchover
during
running
.
33
Frequency
source
switchover
When
P0
-
18
is
set
to
2
,
this
terminal
is
used
to
perform
switchover
between
main
frequency
source
X
and
auxiliary
frequency
source
Y
.
When
P0
-
18
is
set
to
3
,
this
terminal
is
used
to
perform
switchover
between
main
frequency
source
X
and
X
+
Y
.
When
P0
-
18
is
set
to
2
,
this
terminal
is
used
to
perform
switchover
between
auxiliary
frequency
source
Y
and
X
+
Y
.
34
Lock
running
frequency
When
this
terminal
is
ON
,
the
current
running
frequency
is
locked
,
and
remains
valid
at
power
-
failure
.
35
Select
main
frequency
source
Terminal
with
Function
36
Terminal
with
Function
35
Frequency
Source
0
0
Setting
of
P0
-
18
0
1
Main
frequency
source
1
0
Auxiliary
frequency
source
1
1
Setting
of
P0
-
18
36
Select
auxiliary
frequency
source
37
Motor
switchover
during
running
When
this
terminal
is
ON
,
the
AC
drive
controls
motor
2
;
when
this
terminal
is
OFF
,
the
AC
drive
controls
motor
1
.
The
switchover
can
be
performed
during
running
.
After
the
stop
delay
set
in
P3
-
14
,
the
AC
drive
outputs
the
motor
switchover
signal
.
After
the
delay
set
in
P3
-
15
,
the
AC
drive
starts
again
.
•
Function 30
(
Command source switchover to operation panel control
)
takes
Содержание VDF730 Series
Страница 1: ...VDF730 Series...
Страница 7: ......
Страница 8: ...1 Safety Information and Precautions...
Страница 15: ...Safety Information and Precautions VDF730 User Manual 14...
Страница 16: ...2 Product Information...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Страница 52: ...4 Operation and Display...
Страница 75: ...Operation and Display VDF730 User Manual 74...
Страница 76: ...5 Function Code Table...
Страница 97: ...Function Code Table VDF730 User Manual 96...
Страница 98: ...6 Description of Function Codes...
Страница 153: ...Description of Function Codes VDF730 User Manual 152...
Страница 154: ...7 EMC...
Страница 158: ...8 Troubleshooting...
Страница 165: ...Troubleshooting VDF730 User Manual 164...