Operation
and
Display
VDF730
User
Manual
-
68
-
Note
• In
the
fxed
length
control
mode
,
the
direction
cannot
be
identifed
and
only
the
length
shall
be
calculated
based
on
the
number
of
pulses
.
• Only
DI5
can
be
allocated
with
the
function
"
Length
count
input
".
• An
automatic
stop
system
can
be
implemented
if
the
length
reached
signal
output
by
the
DO
is
fed
back
to
the
AC
drive
input
terminal
with
the
stop
function
.
Figure
4
-
26
Common
application
example
of
the
fxed
length
control
function
M
DI4
VDF730
DI3
DI2
COM
P2
-
03
=
25
,
P2
-
04
=
26
P7
-
07
(
Number of
pulses
permeter
)
RUN button
JOG button
Length pulses input
CME
DI1
Stop button
Relay outputput
Button for
clearing length
DI5
Length
reached output
Length
detection
sensor
Winding
motor
P0
-
00
=
1
,
P2
-
00
=
1
P2
-
01
=
3
,
P2
-
02
=
4
P2
-
05
=
2
P3
-
01
=
12
P7
-
05
(
Set length
)
TA
/
TB
4
.
6
.
10
Use
of
the
Counting
Function
The
count
value
needs
to
be
collected
by
the
DI
terminal
that
is
allocated
with
function
23
.
When the count value reaches P7
-
08
(
Set count value
),
the DO terminal allocated with
function
10
(
Set
count
value
reached
)
becomes
ON
.
Then
the
counter
stops
counting
.
When
the
count
value
reaches
P7
-
09
(
Designated
count
value
),
the
DO
terminal
allocated
with
function
11
(
Designated
count
value
reached
)
becomes
ON
.
The
counter
continues
to
count
until
"
Set
count
value
"
is
reached
.
Figure
4
-
27
Parameter
setting
in
the
counting
mode
P2
-
00 to P2
-
09
=
23
(
Counting
pulses input
)
P2
-
00 to P2
-
09
=
24
(
Counting reset
)
Counting
pulses
Counting
reset
P7
-
13
(
Counting value
)
P7
-
09
(
Designated
counting value
)
≥
P3
-
01 to P3
-
04
=
10
(
Designated
counting value reached
)
Reset
Clear
to
0
After the
designated
counting value is
reached
,
the DO terminal
becomes ON
(
1
).
≥
P7
-
08
(
Set counting
value
)
P3
-
01 to P3
-
04
=
11
(
Set counting
value reached
)
Reset
After the
set counting
value is reached
,
the
DO terminal
becomes ON
(
1
).
Counting reset
input
Designated counting
value reached output
Set counting value
reached output
Counting
pulses input
P7
-
09
=
11
1 2 3
10 11 12
19 20 21
P7
-
08
=
20
1 2
Содержание VDF730 Series
Страница 1: ...VDF730 Series...
Страница 7: ......
Страница 8: ...1 Safety Information and Precautions...
Страница 15: ...Safety Information and Precautions VDF730 User Manual 14...
Страница 16: ...2 Product Information...
Страница 30: ...3 Mechanical and Electrical Installation...
Страница 51: ...Mechanical and Electrical Installation VDF730 User Manual 50...
Страница 52: ...4 Operation and Display...
Страница 75: ...Operation and Display VDF730 User Manual 74...
Страница 76: ...5 Function Code Table...
Страница 97: ...Function Code Table VDF730 User Manual 96...
Страница 98: ...6 Description of Function Codes...
Страница 153: ...Description of Function Codes VDF730 User Manual 152...
Страница 154: ...7 EMC...
Страница 158: ...8 Troubleshooting...
Страница 165: ...Troubleshooting VDF730 User Manual 164...