CABLING AND CONNECTIONS
vacon • 49
24-hour s358 (0)201 212 575 • Email: [email protected]
6
6.2.7.2
12-pulse drives
Table 17. Cable and aR fuse sizes for Vacon NX_6, 12-pulse supply
Frame
Type
I
L
[A]
Bussmann
/Ferraz Shawmut
fuse type
Fuse I
n
[A]
Mains and motor
cable
1)
[mm
2
]
No of
supply
cables
No of
motor
cables
FR10
NXC0261 6
261
170M5813 (6 pcs)
NH2UD69V500PV (6 pcs)
700/500
Cu: 2*(3*120+70)
Al: 2*(3*185Al+57Cu)
Even
Even/Odd
NXC0325 6
325
170M5813 (6 pcs)
NH2UD69V500PV (6 pcs)
700/500
Cu: 2*(3*120+70)
Al: 2*(3*185Al+57Cu)
Even
Even/Odd
NXC0385 6
385
170M5813 (6 pcs)
NH2UD69V500PV (6 pcs)
700/500
Cu: 2*(3*120+70)
Al: 2*(3*185Al+57Cu)
Even
Even/Odd
NXC0416 6
416
170M5813 (6 pcs)
NH2UD69V500PV (6 pcs)
700/500
Cu: 2*(3*150+70)
Al: 2*(3*185Al+57Cu)
Even
Even/Odd
FR11
NXC0460 6
460
170M5813 (6 pcs)
NH2UD69V700PV (6 pcs)
700
Cu: 2*(3*150+70)
Al: 2*(3*240Al+72Cu)
Even
Even/Odd
NXC0502 6
502
170M5813 (6 pcs)
NH2UD69V700PV (6 pcs)
700
Cu: 2*(3*185+95)
Al: 2*(3*300Al+88 Cu)
Even
Even/Odd
NXC0590 6
590
170M5813 (6 pcs)
NH2UD69V700PV (6 pcs)
700
Cu: 2*(3*240+120)
Al: 4*(3*120Al+41Cu)
Even
Even/Odd
FR12
NXC0650 6
650
170M5813 (6 pcs)
NH2UD69V700PV (6 pcs)
700
Cu: 4*(3*95+50)
Al: 4*(3*150Al+41Cu)
Even
Even
NXC0750 6
750
170M5813 (6 pcs)
NH2UD69V700PV (6 pcs)
700
Cu: 4*(3*120+70)
Al: 4*(3*150Al+41Cu)
Even
Even
NXC0820 6
820
170M5813 (6 pcs)
NH2UD69V700PV (6 pcs)
700
Cu: 4*3*150+70)
Al: 4*(3*185Al+57Cu)
Even
Even
FR13
NXC0920 6
920
No additional drive fuses needed
Cu: 4x(3x150+70)
Al: 4x(72Cu)
Even
Even/Odd
NXC1030 6
1030
No additional drive fuses needed
Cu: 4x(3x185+95)
Al: 6x(3x150+41Cu)
Even
Even/Odd
NXC1180 6
1180
No additional drive fuses needed
Cu: 6x(3x185+95)
Al: 6x(3x185+72Cu)
Even
Even/Odd
FR14
NXC1500 6
1500
No additional drive fuses needed
Cu: 8*(3*185+95)
Al: 8*(3*185+57Cu)
Even
Even
NXC1900 6
1900
No additional drive fuses needed
Cu: 8*(3*240+120)
Al: 8*(3*240+72Cu)
Even
Even
NXC2250 6
2250
No additional drive fuses needed
Cu: 8*(3*240+120)
Al: 8*(3*300+88Cu)
Even
Even
1)
Based on correction factor 0.7. Cables are laid on a cable ladder side by side, three ladders on top of each
other. Ambient temperature is 30 °C (86 °F). EN60204-1 and IEC 60364-5-523.