4
vacon • 20
TECHNICAL DATA
Tel. +358 (0) 201 2121 • Fax +358 (0)201 212 205
Ambient conditions
Ambient operating tem-
perature
–10 °C (no frost)…+40 ºC
Storage temperature
–40 °C…+70 °C
Relative humidity
0 to 95% RH, non-condensing, non-corrosive,
no dripping water
Air quality:
-
chemical vapours
-
mechanical
particles
IEC 721-3-3, unit in operation, class 3C2
IEC 721-3-3, unit in operation, class 3S2
Cabinet surface treat-
ment
Nanoceramic pretreatment. Anodic dipcoat-priming
and textured powder-coating.
Altitude
100% load capacity (no derating) up to 1,000 m
1-% derating for each 100m above 1000;
max. 3000 m (690 V max 2000 m).
Vibration
EN50178/EN60068-2-6
Displacement amplitude 0.25 mm (peak) at 5…31 Hz
Max acceleration 1 G at 31…150 Hz
Use anti-vibration mountings under the drive if
extra vibration resistance is required.
Shock
EN50178, EN60068-2-27
UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15 G, 11 ms (in package)
Enclosure class
IP21/NEMA1 standard in entire kW/HP range
IP54/NEMA12 option in entire kW/HP range
Pollution degree PD2
EMC (at default
settings)
Immunity
Fulfils all EMC immunity requirements
Emissions
EMC level L: EN 61800-3 (2004), Category C3
EMC level T: Low earth-current solution for IT-
networks, EN 61800-3 (2004), Category C4 (can be
modified from level L units.
Safety
EN 50178 (1997), EN 60204-1 (1996), EN 60950
(2000, 3rd edition) (as relevant), CE, UL, CUL, EN
61800-5; (see unit nameplate for more detailed
approvals).
IEC 60664-1 and UL840 in overvoltage category III.
Table 6. Technical data
Содержание nxp/c
Страница 1: ...vacon nxp c ac drives user manual ...
Страница 2: ......
Страница 110: ......