6
vacon • 42
CABLING AND CONNECTIONS
Tel. +358 (0) 201 2121 • Fax +358 (0)201 212 205
Figure 23. Components of the cable gland set
Installing the cable gland
Unless the cable gland is already installed by the manufacturer, follow the procedure below to do
this:
1.
Assemble the rubber sealing in the narrow groove of the bush ring. Make sure that the
gap between the assembly plate and the sealing is tight.
2.
Since the fastening spring is rather stiff, we recommend to use a cone-shaped tool to fit
the metal sock in the bush ring and then to clamp it with the spring bent into a ring
shape. Draw the sock over the groove far enough to be easily fastened with the spring.
Make sure that the spring clamps the sock at 360°.
3.
Roll up the sock as far as the fastening ring and remove the cone-shaped tool if used.
Now the cable installation is easier and the cable will not damage the sock.
4.
Clamp the sock to the shielding of cable with a cable tie.
Rubber sealing
Bush ring
Cable
Assembly plate
PE(N) screen
Metal sock
Fastening spring
Cable tie
11502_uk
Cone-shaped tool
Metal sock
Fastening spring
11503_uk