Multi-purpose Control Application II
Multi-purpose Control Application II
Multi-purpose Control Application II
Multi-purpose Control Application II
Multi-purpose Control Application II
Vacon Plc
Phone:
+358-(0)201 2121
Fax: +358-(0)201 212 205
Service:
+358-40-8371 150
E-mail: [email protected]
Note!
Note!
Note!
Note!
Note!
STOP
STOP
STOP
STOP
= Parameter value can be changed only when the frequency converter is stopped. (Continues)
Code
Parameter
Range
Step
Default
C
u
s
t
o
m
Description
Page
3.1
Analogue output func-
tion
0—14
1
1
0 = Not used
1 = O/P frequency
2 = Motor speed
3 = O/P current
4 = Motor torque
5 = Motor power
6 = Motor voltage
7 = DC-link volt.
8 = Input signal U
in
9 = Input signal I
in
10 = Refer. freq.
11 = Refer. torque
12 = Motor±torque
13 = Motor±power
14 = O/P freq.
Scale 100%
(0—f
max
)
(0—max. speed
(0—2.0 x I
nCX
)
(0—2 x T
nCX
)
(0—2 x P
nCX
)
(0—100% x U
nM
)
(0—1000 V)
(-2--+2xT
nMOT
)
(-2--+2xT
nMOT
)
(f
min
—f
max
)
26
3.2
Analogue output filter
time
0.01—10 s
0.01
1.00
26
3.3
Analogue output inver-
sion
0—1
1
0
0 = Not inverted
1 = Inverted
26
3.4
Analogue output mini-
mum
0—1
1
0
0 = 0 mA
1 = 4 mA
26
3.5
Analogue output scale
10—1000%
1%
100%
26
3.6
Digital output function
0—22
1
1
0 = Not used
1 = Ready
2 = Run
3 = Fault
4 = Fault inverted
5 = Vacon overheat warning
6 = External fault or warning
7 = Reference fault or warning
8 = Warning
9 = Reversed
10 = Jogging speed selected
11 = At speed
12 = Motor regulator activated
13 = Output frequency limit superv. 1
14 = Output frequency limit superv. 2
15 = Torque limit supervision
16 = Reference limit supervision
17 = External brake control
18 = Control from I/O terminals
19 = Frequency converter temperature
limit supervision
20 = Unrequested rotation direction
21 = External brake control inverted
22 = Termistor fault or warning
27
3.7
Relay output 1 function
0—22
1
2
As parameter 3.6
27
3.8
Relay output 2 function
0—22
1
3
As parameter 3.6
27
3.9
Output frequency limit 1
supervision function
0—2
1
0
0 = No
1 = Low limit
2 = High limit
27
3.10
Output frequency limit 1
supervision value
0—f
max
(par. 1.2)
0.1 Hz
0 Hz
27
3.11
Output frequency limit 2
supervision function
0—2
1
0
0 = No
1 = Low limit
2 = High limit
27
3.12
Output frequency limit 2
supervision value
0—f
max
(par. 1.2)
0.1 Hz
0 Hz
27
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
STOP
Group 3, Output and supervision parameters
Group 3, Output and supervision parameters
Group 3, Output and supervision parameters
Group 3, Output and supervision parameters
Group 3, Output and supervision parameters