Select this parameter depending on the position (superior or inferior) of
the gate leaf in motion
SUP
the gate leaf in motion is the leaf that should open first
inF
the gate leaf in motion is the leaf that should open second
PLEASE NOTE: if installation envisages one motor only, select
SUP
Select this parameter depending on the direction of opening of gate leaf 1
AP1
the gate leaf is opening
Ch1
the gate leaf is closing
Having selected this parameter, the control unit moves the SLAVE
motor
1
If the control unit detects the SLAVE motor, the display shows
AP2
Select this parameter depending on the direction of opening of gate leaf 2
AP2
the gate leaf is opening
Ch2
the gate leaf is closing
Having selected the parameter, press
OK
to move to the next phase.
If the display shows
Er93
, this means the SLAVE motor is connected
incorrectly.
Check the SLAVE motor connection and repeat the initialisation
procedure
2
If the control unit does NOT detect the SLAVE motor, the display
shows
SinG
If the installation envisages only one motor, press
OK
to move to the
next phase.
If the installation envisages two motors, select the
doP
menu option and
press
OK
.
The display will show
Er94
to indicate that the SLAVE motor is not
connected, or is connected incorrectly.
Check the SLAVE motor connection and repeat the initialisation
procedure
3
If the control unit does not detect a photocell on the PHOTO input,
the display shows
Ft.no
If the installation does not envisage the use of a photocell, select
Ft.no
and press
OK
to move to the next phase.
The photocell will be automatically disabled.
If installation envisages the use of a photocell, select
Ft.Si
and press
OK
.
The display will show
Er91
to indicate that the photocell is not
connected, or is connected incorrectly.
Check the photocell connection and repeat the procedure.
4
If the control unit detects a photocell connected correctly to the
PHOTO input, it automatically switches to the working time
self-training phase.
Press
OK
to start the self-training phase.
Select
ESC
and press
OK
to exit the menu without performing the time
self-training phase.
Please note: in the case of exiting without self-training, it will not
be possible to operate the gate.
In any case, it will be possible to perform self-training in a separate
phase and program the remainder of the control unit functions, using
the specific menu.
Содержание ZARISS Series
Страница 2: ......
Страница 14: ...ITALIANO 12 4 17 RIEPILOGO COLLEGAMENTI ELETTRICI Fase alimentazione 230Vac Terra Neutro alimentazione 230Vac ...
Страница 34: ...ITALIANO 32 ...
Страница 46: ...ENGLISH 44 4 17 ELECTRICAL CONNECTION SUMMARY Phase power supply 230Vac Earth Neutral power supply 230Vac ...
Страница 66: ...ENGLISH 64 ...
Страница 98: ...FRANÇAIS 96 ...
Страница 110: ...ESPAÑOL 108 4 17 RESUMEN DE CONEXIONES Fase de alimentación 230Vac Tierra Neutro alimentación 230Vac ...
Страница 130: ...ESPAÑOL 128 ...
Страница 131: ......
Страница 132: ......