3.4 - MOTOR UNBLOCKING
In the case of a power failure, the gate can be unblocked
by operating the motor:
1.
Open the lock cover
J
located on the front of the motor
2.
Insert the key
L
into the hole and turn clockwise until
reaching the end-stop
To reset the automation device, proceed as follows:
1.
Turn the key
L
anti-clockwise until reaching the end
stop and then extract it
2.
Close the lock using the cover
J
3.5 - FIXING THE OPENING
MECHANICAL STOP
1.
Release the motor reducer
2.
Open the leaf/door to its maximum opening position
3.
Position stop
M
in close contact with the arm
4.
Tighten the screws
N
5.
Loosen the screws fixing the straight arm to the motor
reducer
6.
Position the casing
D
on the straight arm and tighten
the screw
E
after having inserted the washer
P
and the
grower
Q