DISPLAY
DATA
DESCRIPTION
DEFAULT MEMO
Foto
Exterior photocell input
This menu makes it possible to enable the exterior photocell input, i.e.
inactive during opening (see the section regarding installation).
CFCh
CFCh
Input enabled even at standstill gate too: the opening movement does not
start if photocell is interrupted
no
Input disabled (ignored by the control unit)
Ch
Input enabled for the closing phase only.
WARNING: if you select this option, you must disable photocell test
Fot.i
Interior photocell input
This menu makes it possible to enable the interior photocell input, i.e.
active during opening and closing (see the section regarding installation).
no
no
Input disabled (ignored by the control unit)
AP.Ch
Input enabled
Ft.tE
Test of the photocells
Si
no - Si
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
CoS1
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon (fixed ribbons)
no
no
Input disabled (ignored by the control unit)
AP
Input enabled during the opening and disabled during the closure
APCh
Input enabled in opening and closure
CoS2
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to
say mobile ribbons
no
no
Input disabled (ignored by the control unit)
Ch
Input enabled during closure and disabled during opening
APCh
Input enabled in opening and closure
Co.tE
Test of the safety edges
This menu allows setting the method of control of the safety edges working
no
no
Test disabled
rESi
Test enabled for conductive rubber safety edges
Foto
Test enabled for optical safety edges
riLA
Motor Release on Mechanical Stop
When the gate halts against the mechanical stop, the motor is controlled for a
fraction of a second in the opposite direction, decreasing the motor gear
tension
2
0
Function disabled
1 - 10
Time motor release (max. 1 second)
FinE
End of Programming
This menu allows to finish the programming (both default and personalized)
saving the modified data into memory
no
no
Do not quit the programming
Si
Exit from the programming menu, storing the parameters set
Содержание ZARISS Series
Страница 2: ......
Страница 14: ...ITALIANO 12 4 17 RIEPILOGO COLLEGAMENTI ELETTRICI Fase alimentazione 230Vac Terra Neutro alimentazione 230Vac ...
Страница 34: ...ITALIANO 32 ...
Страница 46: ...ENGLISH 44 4 17 ELECTRICAL CONNECTION SUMMARY Phase power supply 230Vac Earth Neutral power supply 230Vac ...
Страница 66: ...ENGLISH 64 ...
Страница 98: ...FRANÇAIS 96 ...
Страница 110: ...ESPAÑOL 108 4 17 RESUMEN DE CONEXIONES Fase de alimentación 230Vac Tierra Neutro alimentación 230Vac ...
Страница 130: ...ESPAÑOL 128 ...
Страница 131: ......
Страница 132: ......