DISPLAY
DATA
DESCRIPTION
DEFAULT MEMO
St.AP
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
St.Ch
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase
StoP
StoP
The gate stops and its cycle is considered as finished
APEr
The gate opens again
St.PA
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase
ChiU
ChiU
The gate starts closing
no
Command is ignored
PAUS
The pause time is reset (
Ch.AU
)
SPAP
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase
PAUS
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate goes on with the opening phase (command is ignored)
Ch.AU
Automatic closing
In automatic mode, the control unit automatically recloses the gate on
expiry of the time limit set in this menu
no
no
Function deactivated
0.5”-20.0’
The gate recloses after the set period time
(adjustable time from 0.5” to 20.0’)
Ch.tr
Closing after transit
During the automatic operation, the pause count down starts from the set up
value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be immediately
stored as pause time.
This function allows having a fast closing as soon as transit through the gate is
completed, therefore, a time shorter than Ch.AU is generally used.
Ch.AU
will be used when no is set up.
no
no
Function deactivated
0.5”-20.0’
The gate recloses after the set period time
(adjustable time from 0.5” to 20.0’)
PA.tr
Pause after transit
no
no - Si
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is
Ch.tr
Содержание ZARISS Series
Страница 2: ......
Страница 14: ...ITALIANO 12 4 17 RIEPILOGO COLLEGAMENTI ELETTRICI Fase alimentazione 230Vac Terra Neutro alimentazione 230Vac ...
Страница 34: ...ITALIANO 32 ...
Страница 46: ...ENGLISH 44 4 17 ELECTRICAL CONNECTION SUMMARY Phase power supply 230Vac Earth Neutral power supply 230Vac ...
Страница 66: ...ENGLISH 64 ...
Страница 98: ...FRANÇAIS 96 ...
Страница 110: ...ESPAÑOL 108 4 17 RESUMEN DE CONEXIONES Fase de alimentación 230Vac Tierra Neutro alimentación 230Vac ...
Страница 130: ...ESPAÑOL 128 ...
Страница 131: ......
Страница 132: ......