9 - LOADING THE DEFAULT PARAMETERS
If necessary, it is possible to restore all parameters to their standard or default values (see the final summary table).
m
PLEASE NOTE: This procedure results in the loss of all customised parameters, and hence it has been included outside the
configuration menu, in order to minimise the likelihood of it being run in error.
Loading of the default parameters is performed each time the initialisation procedure is performed (even without working
time self-training).
The parameters acquired during initialisation are maintained, even when the default parameters are loaded.
1.
Press and hold the
OK
key until the display shows
-dEF
2.
Release the
OK
key: the display shows
ESC
(only press the
OK
key if it is desired to exit this menu)
3.
Press the
i
key: the display shows
dEF
.
4.
Press the
OK
key: the display shows
no
5.
Press the
i
key: the display shows
Si
6.
Press the
OK
key: all parameters are overwritten with their default values (see the table on pages 74-75), the control units exits
programming mode and the display shows the control panel.
Содержание ZARISS Series
Страница 2: ......
Страница 14: ...ITALIANO 12 4 17 RIEPILOGO COLLEGAMENTI ELETTRICI Fase alimentazione 230Vac Terra Neutro alimentazione 230Vac ...
Страница 34: ...ITALIANO 32 ...
Страница 46: ...ENGLISH 44 4 17 ELECTRICAL CONNECTION SUMMARY Phase power supply 230Vac Earth Neutral power supply 230Vac ...
Страница 66: ...ENGLISH 64 ...
Страница 98: ...FRANÇAIS 96 ...
Страница 110: ...ESPAÑOL 108 4 17 RESUMEN DE CONEXIONES Fase de alimentación 230Vac Tierra Neutro alimentación 230Vac ...
Страница 130: ...ESPAÑOL 128 ...
Страница 131: ......
Страница 132: ......