ENGLISH
- 50 -
PARAMETER
VALUE
SUBMENU DESCRIPTION
DEFAULT
CHAPTER
MEMO
RX
Receiver mode
START
20
START
Channel 1 = START
Channel 2 = PARTIAL START
APCH
Channel 1 = OPEN
Channel 2 = CLOSE
STOP
Stop command function
PROS
19
PROS
Stop then resume
CHIU
Close then hold
APRE
Open then hold
INVE
Stop then invert
FOT1
Photocell 1 mode
NO
11
NO
P.AP.F
0-100%
No function
HOOK
Anti-dragging function
MASK
Enabled in closing and with masked operation
APCH
Enabled in opening and closing
FOT2
Photocell 2 mode
APCH
11
APCH
P.AP.F
0-100%
Enabled in opening and closing
P.AP.F
= 0%
NO
No function
HOOK
Anti-dragging function
MASK
Enabled in closing and with masked operation
FT.TE
0.1”-2.0”
Photocell test enable
NO
11.2
NO
Function disabled
COS1
Safety ribbon 1 mode
NO
12.3
NO
No function
AP
Enabled opening
APCH
Enabled opening and closing
CH
Enabled closing
COS2
Funzione costa sensibile 2
NO
12.3
NO
No function
AP
Enabled opening
APCH
Enabled opening and closing
CH
Enabled closing
CO.TE
Ribbon type and test
NO
12.3
NO
Mechanic - no test
RESI
Resistive
FOTO
Optical with test
ENCO
Encoder enable
NO
17-18
NO
No function
INTRM
Intermediate positions
EN.1C
1-channel encoder
EN.2C
2-channel encoder