ENGLISH
- 49 -
PARAMETER
VALUE
SUBMENU DESCRIPTION
DEFAULT
CHAPTER
MEMO
REL2
Relay 2 set up
NO
23
NO
No function
CUST
Custom
23.7
ATTES
Relay contact closed while waiting for
commands
APERT
Relay contact closed during tests and the
opening
CHIUS
Relay contact closed when closing
PAUSA
Relay contact closed during the pause
ARRES
Relay contact closed when the door is open
and automatic closing is disabled (parameter
CH.AU
)
TEST
12Vdc test
CHIU
Close command
SERV
Service indicator
LUCI
Courtesy lights
ING1
Input 1 set up
APRE
19
START
Start cycle (N.O. contact)
NO
No function
CHIU
Always close (N.O. contact)
APRE
Always open (N.O. contact)
STOP
Stop (N.C. contact)
ST.PE
Partial open (N.O. contact)
ING2
Input 2 set up
CHIU
19
ST.PE
Partial open (N.O. contact)
START
Start cycle (N.O. contact)
NO
No function
CHIU
Always close (N.O. contact)
APRE
Always open (N.O. contact)
STOP
Stop (N.C. contact)
ING3
Input 3 set up
NO
19
NO
No function
PRES
Force dead man mode (N.O. contact)
STOP
Stop (N.C. contact)
ST.PE
Partial open (N.O. contact)
START
Start cycle (N.O. contact)