Default value loading
The value of all menu items can be brought to a standard value (see
final recap table) by means of only one command. There are two sets of
values available:
AntE
Values for a two-leaf gate equipped with a lock.
SCor
Values for a one-leaf sliding gate without lock.
After loading default values, the other menu items can be scrolled and
each parameter can be changed; exit from default menu will cause the
automatic selection of the next item.
Leaf 1 opening time
Motor 1 will be operated for the setup time in the opening phase;
in case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
Leaf 2 opening time
Motor 2 will be operated for the setup time in the opening phase;
In case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
WARNING:
if motor 2 is not connected, this time must be set to
zero; in this circumstance, the control unit will not consider all
configurations of motor 2 and door phase difference times as well.
Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will open
leaf 1 only, for a shorter time. Max allowed time to be setup is
t.AP1
.
CONTROL UNIT CONFIGURATION
This paragraph concerns the step-by-step procedure to set all operation parameters of
CITY1
control unit. You can either
follow all procedure steps and perform a complete control unit configuration or select and adjust interesting items only.
As for both cases, you will have to perform the right exit procedure through item
FinE
, in order to activate your new configuration.
CITY1
control unit provides for a self-learning procedure of working times; therefore, we recommend that you set up a standard
configuration first (see previous paragraph), then you carry out the self-learning and finally you change any unsatisfactory items.