Motor 1 power
This menu allows adjusting the motor 1 power.
The displayed value is the percentage of max. motor power.
WARNING:
In case an hydraulic motor is used, set value 100.
Soft start (slowed down)
In case this function is enabled, during the first seconds of motion of
each door, the control unit will give motors a reduced power
command, for a softer start.
Slowing down time
In case this function is enabled, during the last seconds of motion of
each door, the control unit will give motors a reduced power
command, to avoid a strong impact with the stop end.
t.AP1
is the
max. allowed time.
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to
measure both opening and closing times, and to enable it again once
the setup has been carried out. The control unit will automatically
consider the working time delay caused by the slowing down.
• If partial opening time t.APP is shorter than t.AP1, there will be no
slowing down during the pedestrian cycle opening.
Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, its doors could not
move.
In case the
SPUn
(pickup) function is activated, for the first 2 seconds of
motion of each door, the control unit will ignore both
Pot1
and
Pot2
values and it will give motors the maximum power command in order to
overcome the gate inertia.
Motor 2 power
This menu allows adjusting the motor 2 power.
The displayed value is the percentage of max. motor power.
WARNING:
In case an hydraulic motor is used, set value 100.