E
N
G
L
IS
H
40
Safety ribbon 1 input
This menu allows enabling the input for type 1 safety ribbon, that is to
say, fixed ribbons (see paragraph “Installation”).
no
Input disabled (ignored by the control unit).
No jumper with the common is required.
Si
Input enabled.
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to
say mobile ribbons (see paragraph “Installation”).
no
Input disabled (ignored by the control unit).
No jumper with the common is required.
Si
Input enabled.
End of Stroke Inputs
CITY1
control unit allows connecting four mechanical ends of stroke
(normally closed contacts) which are activated by the door motion and
showing to the control unit that each door reached its position of
complete opening or closing.
no
End of stroke inputs are disabled.
Si
End of stroke inputs are enabled.
Motor Release on Mechanical Stop
When the gate halts against the mechanical stop, the motor is
controlled for a fraction of a second in the opposite direction,
decreasing the motor gear tension.
Si
Function enabled
no
Function disabled
Limit switch / Encoder input (only CITY1-ECD)
The CITY1-ECD controller allows you to connect four mechanical limit
switches (normally closed contacts) or two encoders.
The limit switches are activated by the gate panel motion and inform
the controller that each gate has reached the totally open or closed
position.
The encoders inform the controller of the exact position of each gate.
no
Inputs disabled (the controller ignores them).
It is not necessary to jumper with neutral.
EnCo
Inputs enabled as encoders
FC
Inputs enabled as limit switches.