Upstream Instruction Manual
Released on 5/1/10 – R800001L
Page 22
UV Pure Technologies Inc. © 2010
Amber Light – situated in the middle, an illuminated amber light may indicate the
Initial Set-up process has begun or a warning of some condition that, if not
addressed, could impact the Upstream’s performance. Warnings should be
addressed as soon as possible. Warnings are accompanied with a single beep,
messages and troubleshooting tips on the LCD display.
Red Light – situated at the top, an illuminated red light indicates an alarm which
has significantly impacted the Upstream’s performance and it must be addressed
immediately. Alarms are accompanied with continuous beeping, messages and
troubleshooting tips on the LCD display.
Audio Alarm
The audio alarm or beeper, will alert the operator to any conditions out of the
ordinary, A single beep will sound if a warning occurs; continuous beeping will
sound if an alarm occurs – see Menu & Troubleshooting Section for more details
on warning and alarms. The audio alarm may be disabled temporarily or
permanently in the Service Menu.
Starting the Unit
Caution: Do not operate unit with the front panel or ballast enclosure door
open. Do not try to open the front panel or ballast enclosure door when the
unit is operating
– Shutdown and unplug the unit first before trying to gain
access. The Upstream contains a safety switch that will disable the lamp power
supply (ballast) if the front panel is not completely closed.
Caution: Do not operate unit dry.
There must be water in the treatment
chamber to prevent damage to internal components. In the event of a lack of
water or water supply being turned off, shutdown the unit until the water supply
can be restored. In the event of a power failure, the unit will shut down and the
solenoid valve (optional) will close, preventing water from flowing. When the
power returns, the unit will automatically restart and perform a self-test. If no
faults are detected, the unit will return to normal operation and the solenoid valve
(optional) will open. Note that even during a brownout, the supply voltage may
drop low enough to cause the unit to shut down. If the unit does not automatically
restart as described above, shutdown and unplug the unit and plug it in again.
Step 1:
Plug the unit into the Transient Voltage Suppressor, and plug the
Transient Voltage Suppressor into a standard grounded outlet. Flip the switch on
the Transient Voltage Surge Suppressor to ON to start the lamps.
Caution:
Never look into or place any exposed skin into the illuminated areas when the
unit is operating.
Step 2:
Once the unit is plugged in, all three lights will illuminate an audible
alarm will sound and the display will become active. This verifies that the lights
and the audible alarm are functioning. The unit then performs a self-test. When
units are new or when the UV lamps have been replaced and lifetime counter
has been reset, the system will begin an Initial Set-up process while the lamps
are reaching full power. The green light will flash and the amber light will be on
solid. This process may last 24 hours. When the Initial Set-up process is