Upstream Instruction Manual
Released on 5/1/10 – R800001L
Page 17
UV Pure Technologies Inc. © 2010
Flushing Instructions
Flushing the system is required after installation or after any disassembly and
cleaning. Flushing may also be required to remove colored water from the unit.
Most filters (if installed) also require flushing prior to use – follow the
manufacturer’s recommendations.
The system may be flushed in two ways. It can be done manually by
disassembling the unit and filling and draining the unit by hand (see Cleaning the
Unit). Flushing may also be done while the unit is operating. Plug in the unit and
open a faucet closest to the unit and run the water for a minimum of 15 minutes.
Control Interfaces
Remote Wireless Monitor (optional)
The Upstream system is available with a remote monitor that monitors the
system operation and alerts you to any change in status. If the unit did not come
with a Remote Monitor, the main unit will display “Radio Initialize Problem” or
“Radio Device Not Installed” upon start up – please ignore this message. If the
unit is equipped with a Remote monitor, install the 9v battery (included) in the
remote monitor and place the monitor in a location of your choice. The remote
will operate up to 164 feet (50m) from the Upstream system location, (Please
note that masonry walls decrease the distance the remote can communicate with
the Upstream system). The remote will run through a diagnostic and then sync
with your Upstream system and display a message indicating unit status. If a
warning or alarm is displayed, detailed information will be available at main unit.
If the remote loses communication with the Upstream, it will display “No Sync”.
Move the monitor to a different location until communication has been
reestablished.
The radio frequency used by the remote is 2.4GHz and has FCC modular
approval grant to meet FCC Part15, EN300 328-1, EN301 489-1, Industry
Canada RSS-211.
Setup procedure
Step 1:
Using the Setup Menu on the main UV Pure unit, select “Bind Remote
Device” and choose a bind number (This is a number from 0 to 40 to differentiate
each unit in parallel or series.) Each Hallett within an approximate 500 feet, line
of sight, range should have a different bind number
.
Once you have chosen a
bind number press Enter. Leave menu display at “Remote Device Bind #”
Step 2:
Pick up the remote monitor and then connect the battery. The remote
will display “Init…, Version # of program and then “UNBOUND” (if never initially
bound). Press and hold the button and the display on the remote monitor will
then show “BINDING”. The button can be released at this point. When the
display on the remote shows “BOUND”, the process is complete. If the unit does
not display “Bound”, repeat the process with a different Bind # on the main unit
(even if a message suddenly appears, repeat the process). It must say “BOUND”
on the remote monitor.