Upstream Instruction Manual
Released on 5/1/10 – R800001L
Page 11
UV Pure Technologies Inc. © 2010
water supply for a number of hours. If disinfection is necessary, all pipes must be
treated and flushed. Once the unit is plugged in, the new UV lamps may take
from a few moments to several hours to reach full power. Having a Lamp Alarm
is normal with a new system (or with newly installed lamps) until the lamps have
reached full power.
Summary of Installation:
Unpack and install Upstream on wall
Install top & bottom hose to unit and to plumbing
Install optional Shutoff solenoid valve
Install optional bypass & drain plumbing
Install purge valve discharge line to a suitable drain line
Connect system power cord to supplied Transient Voltage Surge Suppressor
Connect Transient Voltage Surge Suppressor to grounded power outlet
Assembling the Unit
Step 1:
Unpack the unit, being careful to remove all packaging material. Inspect
the unit for damage particularly the quartz sleeve – See Figure 4A for
disassembly.
Ensure back reflector is completely down
– sometimes
movement in shipping cause the back reflector to slide up. Push down on it until
it rests on the bottom plate of the unit. Check & tighten the fasteners securing the
top and bottom stainless manifolds - see Figure 4B.
Step 2:
The Upstream has four keyhole slots for convenient mounting – all four
should be used.
The unit should be secured vertically to a solid wall large
enough to cover the complete backside of the unit – See Figure 1E. Do not
install the unit horizontally. Remove the top and bottom covers of the unit to
make the mounting holes accessible.
Step 3:
Connect the Stainless flexible hoses to both the top and bottom of the
Upstream. Make sure that the sealing washer is inside the hose end before
making the connection. Tighten securely. Wrap the top hose with pipe insulation.
(Not provided)
Connecting the Pipes
We recommend that a qualified plumber or certified technician perform the water
connections for your Upstream.
Water must flow into the inlet at the bottom of
the unit. The outlet is located at the top of the unit.
Install the optional shutoff
valve before the unit.
Step 1:
Shut off the water supply.
Caution:
Always turn off the water supply
before modifying or disconnecting any piping. Always open a faucet after shutting
off the water supply to relieve water pressure and ensure that the water has been
completely shut off.
Step 2:
If you have decided to install an optional bypass line and drain, you may
begin to install these fittings at this point. See Figure 1B or 1C for more
information on how to connect optional bypass piping and drain.