Product Specifications Table
Models
NC10-75
NC10-50
NC15-75
NC15-50
NC30-75
1"
NC30-75
1.5"
Max. Flow
Rate
1
11 gpm
41 L/min
2.4 m
3
/hr
11 gpm
41 L/min
2.4 m
3
/hr
16.5 gpm
62 L/min
3.7 m
3
/hr
14.6 gpm
55 L/min
3.3 m
3
/hr
28.5 gpm
108 L/min
6.47 m
3
/hr
28.5 gpm
108 L/min
6.47 m
3
/hr
Nominal Flow
Rate
1
10 gpm
38 L/min
2.3 m
3
/hr
10 gpm
38 L/min
2.3 m
3
/hr
15 gpm
57 L/min
3.4 m
3
/hr
13.2 gpm
50 L/min
3.0 m
3
/hr
26.4 gpm
100 L/min
6 m
3
/hr
26.4 gpm
100 L/min
6 m
3
/hr
min. UVT
75%
50%
75%
50%
75%
75%
Operating
Pressure
2
0-100 psig
0-690 kPa
0-100 psig
0-690 kPa
0-100 psig
0-690 kPa
0-100 psig
0-690 kPa
0-100 psig
0-690 kPa
0-100 psig
0-690 kPa
Water Temp.
range
4
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
Air Temp.
range
4
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
34-104° F
1-40° C
Voltage
3
115Vac
115Vac
115Vac
115Vac
115Vac
115Vac
Power Draw
135W
175W
175W
200W
200W
200W
Dry Contact
Yes
Yes
Yes
Yes
Yes
Yes
Remote Monitor
Optional
Optional
Optional
Optional
Optional
Optional
Remote
Start/Stop
Yes
Yes
Yes
Yes
Yes
Yes
Flow Restrictor
Yes
Yes
Yes
Yes
Yes
No
Pressure Drop
at 75% rated
capacity
14 psig
(96 kPa)
14 psig
(96 kPa)
14 psig
(96 kPa)
14 psig
(96 kPa)
14 psig
(96 kPa)
4 psig
(28 kPa)
Inlet & Outlet
Port size
1" MNPT 1" MNPT
1" MNPT
1" MNPT
1" MNPT
1.5"
MNPT
Nominal
Dimensions
(L x W x D)
32x8x9"
(81x20x
23cm)
36x8x9"
(91x20x
23cm)
36x8x9"
(91x20x
23cm)
40x8x9"
(101x20x
23cm)
40x8x9"
(101x20x
23cm)
40x8x9"
(101x20x
23cm)
¹ Flow rates are given in USgpm.
² The optional shutoff valve requires min. 10psig to operate.
3
100-240Vac versions available with same operating specifications.
4
In extreme conditions with both low air and water temperatures, a Thermal Abatement
Kit R400074 may be necessary
The Upstream™ model NC 30-75 with 1” manifolds achieves a dose of 40 mJ per cm
2
at
a maximum restricted flow rate of 28.5 US GPM.
The Upstream™ model NC 30 with 1 ½” manifolds achieves a dose of 40 mJ per cm
2
at
a maximum unrestricted flow rate of 28.5 US GPM. There is no flow restrictor installed as
standard on this model of Upstream, therefore, a flow rate below 28.5 GPM will result in a
dose greater than 40 mJ per cm
2
, and conversely, a flow rate greater than 28.5 US GPM
will result in a lower dose. This model is designed to allow for low pressure drop
applications and can be programmed to achieve target deactivation levels in a broad range
of applications and pre-treatment water quality, in combination with external flow restriction.