SU320CSX
4110-0446, Rev. B
Page 73 of 96
© 2016 UTC Aerospace Systems
Date Printed: 5-Dec-2016
This document does not contain any export controlled technical data.
5.17.12.
Set Application Timer
Description
Sets the status of a timer which is stored in volatile memory.
Resolution is 0.1 second. Register is lost if power is interrupted.
Setting Type
Global
Command AP:TIMER
mode
Parameters
mode
Return Values
none
Range
ON
Reset timer to 0 and start timer
OFF Stop
timer
Type string
Example AP:TIMER
ON
5.17.13.
Get Application Timer
Description
Gets the status of a timer which is stored in volatile memory.
Setting Type
Global
Command AP:TIMER?
Parameters none
Return Values
value (Seconds)
Range N/A
Type String
Example
AP:TIMER? -- query command
105.4 -- return value in seconds
5.17.14.
Get Camera Command List
Description
Returns the camera command list. The list includes commands in
this manual, as well as optional commands beyond the manual’s
scope, support or validation. An optional prefix can be used to
reduce the output list size.
Setting Type
N/A
Command CMDS?
[
prefix
]
Parameters
prefix (optional)
Return Values
value (command)
Range N/A
Type string