SU320CSX
4110-0446, Rev. B
Page 32 of 96
© 2016 UTC Aerospace Systems
Date Printed: 5-Dec-2016
This document does not contain any export controlled technical data.
Range
0 to N, maximum value limited by the number of operational
settings that currently exist.
Type unsigned
integer
Example OPR:START
5
5.5.7.
Get Startup Operational Configuration
Description
Returns the operational slot number that will be loaded on reboot of
the camera.
Setting Type
Global
Command OPR:START?
Parameters none
Return Values
opr_number
Range
0 to N’, maximum value limited by the number of operational
settings that once existed.
Type unsigned
integer
Example
OPR:START?
-- query command
5 --
return
value
5.5.8.
Create New Operational Configuration
Description
Takes the Current Session operational setting and saves it to the
User Configuration memory assigning a new operational slot
number. The operational slot numbers are assigned sequentially.
The new operational slot number will be returned to the host. The
OPR:SAVE command will return an error for camera models where
all available OPR memory slots are populated by factory configured
OPR parameters. Note: When a new operational setting is created,
any factory correction table associated with the current operational
slot will
not
be copied to the new operational slot setting.
Corrections, therefore, must be disabled when using the newly
created configuration slot for meaningful data to be produced.
This
command is only required when users require custom OPR
settings.
Setting Type
N/A
Command OPR:SAVE
Parameters none
Return Values
newly created opr_number
Range
0 to N
Type unsigned
integer
Example OPR:SAVE
--
command
18
--
return
value