SU320CSX
4110-0446, Rev. B
Page 74 of 96
© 2016 UTC Aerospace Systems
Date Printed: 5-Dec-2016
This document does not contain any export controlled technical data.
Example
CMDS? BA -- query command
BAUD:CURRENT
-- response value (beginning with ‘BA’ in
this example)
BAUD:CURRENT? -- cont.
BAUD:FUTURE
-- cont.
BAUD:FUTURE?
-- cont.
CMDS? AGC -- query command
(prefix match, all AGC commands will be output)
CMDS? 4
(outputs in 4 columns)
CMDS? HELP
(display complete help contents for all commands)
CMDS AGC H
display all AGC commands and Help 1 command per line
5.17.15.
Get Camera Command Description
Description
Returns a brief description for a user entered command. Suggested:
the CMDS? function lists the proper command format (CMDS? A
shortens the list by commands only starting with ‘A’ etc.) and then
you can use the camera formatted command in the Help.
Setting Type
N/A
Command HELP?
command
Parameters
[exact command]
Return Values
value (description)
Range N/A
Type string
Example
HELP? OPR -- query command
Sets the camera OPR -- response: text description of the query
5.17.16.
Status and Reset Commands
The user can poll the camera’s error status with the error command, which returns a binary encoded 32-bit
error value. A non-zero error code indicates that an error has occurred. Table 8 below can be used to
decode the error value returned by the error command. A bit value of one indicates an error. Use the
“ON” argument.
Bit
Error
Description Cause
Resolution
0 (LSB) PLL0 error
Internal error
Power cycle camera