8/12
8)
Remove three screws on the lower cover
of the original table.
9)
Open the upper cover of the original table.
10)
Clean the detector plate fitted at the
backside of the original table and the
board with alcohol and wipe them with a
dry cloth.
(Take care not to deform the detector plate
when cleaning it.)
Apply the gel type lubricant to the board.
(Refer to page 1 for details of where to apply
it, etc.)
*If the problem is not solved or a defect
occurs during this work, disconnect the
connector and release the hooks to remove
the board.
Part number of the board:
PARTS PWB SIZE DETECTION ASSY SP
(303M894270)
Screw
Lower cover of original table
Upper cover of the original table
Detector plate
Backside of the upper cover of the
original table
Hook
Board (pattern side)
Connector