![Utax CD 5025 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/utax/cd-5025/cd-5025_technical-bulletin_1064829060.webp)
1/5
Technical Bulletin
UTAX
UTAX
UTAX
CD 5025
P
CD 5025P
CD 5030
P
TA
TA
TA
DC 6025
P
DC 6025P
DC 6030
P
TB 31 / Corrective measures for J9000, J9200 and J9410
2MW-E004/M
Date: 20-02-2014
Only
CD 5025, CD 5030 / DC 6025, DC 6030
C
ONTENT OF CHANGES
:
The paper jam J9000/J9200/J9410 (Note1) may occur due to the following causes.
Thus, the following are changed.
Note1: J9000
No paper feed from DP.
J9200
DP registration sensor non arrival jam.
J9410
DP timing sensor stay jam.
Pheno-
menon
Type Cause
Corrective measures
Ref.
J9000
J9200
J9410
-
A
-
The load by getting narrow the paper
path due to the contact between the
original stopper and the rib of the DP top
cover may be applied to the original
conveying when feeding the original
stack from DP. As a result, the DP motor
may step out and it may cause the
phenomenon in the left.
Corrective measures for the cause
A
-
1) The following are changed to reduce the original stack
feeding by the DP forwarding pulley.
-Weakened the torque of the torque limiter in the DP
paper feed roller ass'y (No.1) from 500gf to 360gf.
-Disused the spacer in the DP paper feed roller ass'y
(No.1) according to the above change.
2) The following is changed to secure the sufficient paper
path even if the original stopper contacts the rib of the
DP top cover.
-Partly cut the shape of the original stopper in the DP
paper feed roller ass'y (No.1).
Corrective measures for the cause
A, B
-
3) The firmware is upgraded to increase the electrical
current for the smooth original conveying from DP.
Page 2
Page 2
Page 4
-
B
-
The load by bumping the single original
with the upward curl against the DP
paper feed roller may be applied to the
original conveying. As a result, the DP
motor may step out and it may cause the
phenomenon in the left.
J9000
-
C
-
If the original detection actuator is
located toward the machine front side
depending on the parts variation, the no-
paper feed jam J9000 may occur that is
caused by the actuator riding on the DP
original sensor.
The following are changed to locate the original detection
actuator toward the machine rear side.
Temporary measures
Added the shim (No.3) to the DP's fulcrum part at the
machine front side.
Permanent measures
Changed the shape of the DP top cover (No.2).
Page 3
Page 3
Содержание CD 5025
Страница 85: ...12 12 LEAFLET FOR APPLYING THE LUBRICANT ...