![Utax CD 5025 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/utax/cd-5025/cd-5025_technical-bulletin_1064829041.webp)
1/2
Technical Bulletin
UTAX
UTAX
UTAX
CD 5025
P
CD 5025P
CD 5030
P
TA
TA
TA
DC 6025
P
DC 6025P
DC 6030
P
TB 21 / Firmware Upgrade (V6.00)
2K3-C210/M
Date: 22-08-2012
T
OPIC
:
The
firmware is upgraded as follows.
C
ONTENT OF CHANGES
:
Corrective measure for the F356 error.
The F356 system error may appear after finishing sending the network fax with simultaneous print function from the network user.
Thus, this is corrected.
Setting [Send and forward].
The destination of [Send and Forward] may be indicated on the status of the sending job when setting [Send and Forward].
Thus, this is so corrected that they are not indicated.
Corrective measure for the F515 error.
The F515 system error may appear if pressing the start key immediately after setting the A3 size original on the DP when setting the
combine 4 in 1 and A5 size paper. Thus, this is corrected.
(This error appears when misalignment occurs depending on the timing of recognizing the original size.)
Corrective measure the "Margin" operation failure.
"Margin" in copy function is not operated if "Auto Image Rotation" is set to "OFF", thus this is corrected.
Corrective measure for the F000, F245 and F248 error. (The error may appear without print operating.).
The error may appear by writing the unnecessary data when the received buffer size is smaller than the received data size due to the
ASIC network processing failure. Thus, the receiving buffer size is expanded.
Correction of the translation in German.
Corrected the following translations in German.
- (Wrong) "Install"
(Correct) "Installiert"
- (Wrong) "Keine Anwort"
(Correct) "Keine Antwort"
- (Wrong) "Universalzuführ"
(Correct) "Universalzufuhr"
- (Wrong) "Prüfen"
(Correct) "Qualität"
- (Wrong) "Druckvorgang läuft"
(Correct) "Drucken"
Corrective measure for the F124 error when scanning.
The F124 system error may appear during scanning the original if pressing the start key from the sending screen after calling up the
function from the registered program. Thus, this is corrected.
Change of the initial setting in the U285 [Setting service status page] for TA/UTAX only.
The initial setting of the maintenance mode U285 is changed from “OFF” to “ON” that was set up for TA/UTAX only. The print coverage is
indicated on the service status page by setting ON in U285.
Change of the timer to enter into the drum refresh.
The timer since the last printing to enter into the drum refresh is changed as below.
1. The timer when returning from the sleep mode is changed from the fixed 60 minutes to the time depending on the temperature/humidity
condition. (This change affects only when setting [Short] or [Standard] in the auto drum refresh mode. The fixed 60 minutes remains
unchanged when setting [Long].)
2. The timer to enter into the drum refresh mode when recovering from the power save mode is changed to 90 minutes.
Change of the display of the black line cleaning guidance.
This is so changed that the black line cleaning guidance is displayed when detecting the black line even if turning on the black line
reduction mode.
Corrective measure for the C1030 service call error [PF lift motor 2 error] (for the optional paper feeder only).
Although the service call error must appear normally by detecting the cassette lift error at continuous five times, that appears actually by
detecting the cassette lift error at total five times. Thus, this is corrected.