3/12
4)
Insert a tool like flat-blade screwdriver and
release two hooks of the original table.
After that, remove the original table.
*Take care so that the original width guide does
not come off from the edge. If coming off,
reattach taking care of the phase with the right
and left side guides.
5)
Clean the detector plate fitted at the backside of
the original table and the board with alcohol and
wipe them with a
dry cloth.
(Take care not to deform the detector plate when
cleaning it.)
Apply the gel type lubricant to the board.
(Refer to page 1 for details of where to apply it,
etc.)
*If the problem is not solved or a
defect occurs
during this work, disconnect the connector and
release the hooks to remove the board.
Part number of the board:
PARTS PWB SIZE DETECTION ASSY SP
(303M894270)
Tool
Original width guide
Original table
Hook
Original table
Detector plate
Hook
Board (Pattern side)
Connector