![Utax CD 5025 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/utax/cd-5025/cd-5025_technical-bulletin_1064829036.webp)
1/5
Technical Bulletin
UTAX
UTAX
UTAX
CD 5025
P
CD 5025P
CD 5030
P
TA
TA
TA
DC 6025
P
DC 6025P
DC 6030
P
TB 20 / Paper empty mis-detection
2K3-C113/M
Date: 04-06-2012
T
OPIC
:
The cassette lift plate may deform by the aged deterioration and the paper position may be lowered if the conditions below
occur at the same time, especially in the case of the main machine cassette. Then, the remaining paper may not reach the
remaining paper detection actuator to cause mis-detection of paper empty. Therefore, the following are changed. Note that
an attention is required when replacing the part and refer to [Field Measure].
Conditions:
- The cassette heater is always turned on. (Heat affected)
- A large stack of maximum size paper is loaded for a prolonged time (Load affected)
C
ONTENT OF CHANGES
:
Content
Affected model
Lift plate
1
The material of the lift plate is changed for heat
resistance. (No.1)
(PC+ABS
PC)
All the affected models
change
Actuator
change
2
The shape of the actuator (No.2) is changed after the
above change 1).
(The new type lift plate is heat-resistant, but less rigid that
may bend and fail to sense paper full. Then, it is
changed as above)
(*)
CD 5025 / DC 6025
CD 5025P / DC 6025P
CD 5030 / DC 6030
PF-470, PF-471
(*) The actuator is not changed for the CDC 5520, CDC 5525 / DCC 6520, DCC 6525 since the shape of the actuator and
mechanical structure.
The lift plate (No.1) and actuator (No.2) are physically compatible between the old and new type, however, the following is
concerned in mixed use.
Cassette
The lift plate deforms and the remaining paper
sensing range for [Low] may shift to cause mis-
detection of [Empty]
Cross-section view
Actuator (No.2)
Actuator
Lift plate
(No.1)
Lift plate
Содержание CD 5025