![Utax CD 5025 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/utax/cd-5025/cd-5025_technical-bulletin_1064829062.webp)
3/5
Mechanism of the phenomenon
C
occurrence
-
(Machine front side) (Machine rear side)
Temporary measures: Adding the shim (No.3)
Permanente measures: Changing the DP top cover (No.2)
X
(Machine front
side)
View from top
Normal condition
Wrong condition
If the original detection actuator is located toward the
machine front side (in the arrow
X
direction) depending
on the parts variation, that actuator may ride on the DP
original sensor, and it may cause misdetection.
(Machine front side)
(Machine rear side)
Original detection actuator
DP top cover
DP original sensor
Original detection actuator
Added the SHIM No.3
1
Added the protrusion
for identification.
Heightened the ribs by 0.3mm
to shift aside the DP top cover
with the original detection
actuator toward the machine
rear side.
Thickened by
0.5mm to shift aside
the actuator toward
the machine rear
side.
Original detection actuator
Содержание CD 5025
Страница 85: ...12 12 LEAFLET FOR APPLYING THE LUBRICANT ...