Maintenance
Description
item No.
2DA/2DB
1-4-30
U157
Checking/clearing the developing drive time
Description
Displays the developing drive time for checking, clearing or changing a figure.
Purpose
To check the developing drive time. Also used to clear the count after replacing the developing unit.
Method
Press the start key. The developing drive time is displayed in minutes.
Clearing
1. Select the CLEAR using the up/down cursor keys.
2. Press the start key. The time is cleared, and the screen for selecting a maintenance item No. is displayed.
Setting
1. Enter a seven-digit drive time (in minutes) using the numeric keys.
2. Press the start key. The time is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the time, press the stop/clear key. The screen for selecting a
maintenance item No. is displayed.
U158
Checking the developing count
Description
Displays the developing count for checking a figure.
Purpose
To check the developing count.
Method
Press the start key. The developing count is displayed.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U161
Setting the fixing control temperature
Description
Changes the fixing control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper, or solve a
fixing problem on thick paper.
Setting
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item to be set using the up/down cursor keys. The screen for executing each item is displayed.
3. Change the setting using the left/right cursor keys.
Display
Description
Setting range
Initial setting
1ST TEMP
Primary stabilization fixing temperature
120 to 185 (°C)
140
2ND TEMP
Secondary stabilization fixing temperature
120 to 185 (°C)
160
COPY TEMP1 Copying operation temperature 1
160 to 220 (°C)
170
COPY TEMP2 Copying operation temperature 2
160 to 220 (°C)
180
COPY CNT
Number of sheets for fixing control
1 to 99
5
THICK CNT
Number of sheets for fixing control (thick paper) 1 to 99
20
Copying operation temperature 1: Temperature in copying operation at the start of copying
Copying operation temperature 2: Temperature in copying operation after the specified number of sheets
for fixing control have passed
Number of sheets for fixing control: The number of sheets to be counted for switching from copying
operation temperature 1 to copying operation temperature 2
The temperatures are to be set such that Secondary stabilization
>
=
Primary stabilization.
4. Press the start key. The value is set.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Содержание cd 1116
Страница 1: ...Service Manual Copy CD 1116 CD 1120 Rev 1 ...
Страница 2: ...Service Manual Copy DC 2116 DC 2120 Rev 1 ...
Страница 4: ...This page is intentionally left blank ...
Страница 247: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Страница 264: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...