![Utax cd 1116 Скачать руководство пользователя страница 193](http://html.mh-extra.com/html/utax/cd-1116/cd-1116_service-manual_1064816193.webp)
2DA/2DB
1-6-25
(2-2) Fitting the scanner wires
Caution:
When fitting the wires, be sure to use those specified below.
Machine front: P/N 2C91236 (gray)
Machine rear: P/N 2C91235 (black)
Fitting requires the following tools:
Two frame securing tools (P/N 2AV6808)
Two scanner wire stoppers (P/N 3596811)
Procedure
1. Remove the screw and then scanner wire
drum gear at the machine rear side.
2. Remove the stop ring and bushing from the
front of the scanner wire drum shaft.
3. Remove the scanner wire drum shaft from the
scanner unit.
Scanner wire
drum gear
Scanner wire drum shaft
Bushing
Stop ring
Figure 1-6-45
Figure 1-6-46