23
1.
With the bypass handle in the bypass position, initiate an immediate regeneration. Ad-
vance through the first 4 cycles to cycle 5. This is the backwash cycle. Each cycle can
be advanced by touching the
“
Go To Next Regen Step
”
button and selecting
“
OK
”
to
advance to the next cycle.
2.
Once the valve has stopped moving and is in the backwash position, slow open the by-
pass handle about 1/8th turn. Water should slowly enter the tank.
NOTE:
If there is a loud knocking sound simply turn the bypass hand back a bit as the sys-
tem is filling too quickly.
3.
During the backwash cycle slowly open the bypass valve until there is water coming
out of the drain hose. Then open the bypass valve fully.
4.
Allow the system to backwash and push all the air out through the drain.
5.
The valve will automatically move to the
“
Rest
”
cycle when the backwash cycle is com-
plete. Skip this cycle by pressing and holding the
“
Set/Change
”
button on the control
valve or by pressing
“
Go to Next Regen Step
”
on the Water Logix App.
6.
This will move the valve to
“
Air Draw
”
cycle. Skip this cycle by pressing and holding
the
“
Set/Change
”
button on the control valve or by pressing
“
Go to Next Regen Step
”
on the Water Logix App.
7.
The valve will then advance to the
“
Rapid Rinse
”
cycle. Allow the system to rinse for
the entire cycle.
8.
Once the system has returned to the Service position after the rinse cycle, the system
is installed and ready for use.
Note:
If the H2O2 option is being utilized, connect the suction tube to the control
valve and install the strainer side of the tube in the peroxide jug. Put the sys-
tem into a regeneration again and allow the each cycle to run in its
’
entirety.