1.
Plug the transformer into the
“
P
”
hole on the valve. The
LED screen will be flashing between the time of day and
the number of days between backwash cycles.
NOTE:
The unit will recharge with air every night. The
days between a full backwash cycle are what the
flashing number represents.
1.
To enter Main Menu, press the Menu/Enter button.
(Time of Day will flash)
2. To set the Time of Day, press the Set/Change button.
(First digit will flash)
Example [12:00]
•
To change digit value, press the Set/Change button.
•
To accept the digit value, press the Menu/Enter button.
•
Next digit will flash to begin setting.
•
Once the last digit display is accepted, all digits will flash.
3. To set A.M. or P.M., press the Menu/Enter button.
•
To change digit value, press the Set/Change button.
Example [ A ]
•
To accept the digit value, press the Menu/Enter button.
•
Once A.M. or P.M. is accepted, the next menu item will flash.
4. Days Between Backwash
•
Press Menu / Enter Button. This display is used to set the maximum amount of time (in
days) the unit can be in service without a backwash. This option setting is identified by
the letter
‘
A
’
in the left digit. Backwash will begin at the set Backwash Time. A
“00”
set-
ting will cancel this feature. The Max Value for this item is 29.
Example:
Every 6 days
(A
-
06) (Default Setting)
•
To Adjust this Value Press the Set / Change Button.
•
To Accept the Digit Value Press the Menu / Enter Button.
5. To set the Number of Days between Air Draw Cycles (d), press the Set/Change Button
•
Repeat instructions from step (2)
Example (d
-
01 )
Notes:1) Maximum value is 9.
2) If value set to 0, air draw is turned off, but an air cycle will still be completed when
backwash cycle occurs. If the Number of Days between Air Draw Cycles is set to a
higher number of days than the Number of Days between Backwash Cycles, it will
have no effect. In order to turn off all cycles, both the Days between Backwash and
Days between Air Draw Cycles must be set to 0.
3) Default setting is 1 day.
6. To Exit Main Menu, press the Menu/Enter button.
Note: If no buttons are pressed for 60 seconds, the Main Menu will be exited automati-
cally