5. Connect the drain hose to the valve and secure it with a hose clamp. Run the drain
hose to the nearest laundry tub, floor drain or approved air gap fitting. The drain can be
ran overhead or down along the floor. Drain tubing should be a minimum of
1/2”
ID.
When running the drain overhead it is important that the tubing has no dips or kinks. If
the drain is ran overhead and must run linearly to the available drain it is recommended
that a hard pipe is used of larger diameter than the drain line. This linear pipe should
have a physical
“
drop
”
toward the drain
(1/2”:10’).
The goal is to have a gravity drain
without back pressure when traveling long distances.
NOTE:
A DIRECT CONNECTION INTO A WASTE DRAIN IS NOT RECOMMENDED.
A PHYSICAL AIR GAP OF AT LEAST
1.5”
SHOULD BE USED TO AVOID
BACTERIA AND WASTEWATER TRAVELLING BACK THROUGH THE
DRAIN LINE INTO THE SYSTEM
.
NOTE:
Be sure to secure the drain line. The System will drain with force and it
should be secured to prevent a leak. Hose clamps should be used to se-
cure the drain line at the connection points.
Hose barb fitting
for drain line.
Be sure to use a
hose clamp to se-
cure the line.