12
Visit us online at www.USWaterSystems.com Give us a call at: 1
-
800
-
608
-
8792
Installation Instructions
1.
If your hot water tank is electric, turn off the power to it to avoid damage to the element
in the tank.
2.
If you have a private well, turn the power off to the pump and then shut off the main
water shut off valve. If you have municipal water, simply shut off the main valve. Go to
a faucet or spigot, (preferably on the lowest floor of the house) turn on the cold water
until all pressure is relieved and the flow of water stops.
3.
Locate the System tank and brine tank close to a drain where the system will be in-
stalled. The surface should be clean and level.
NOTE:
Any solder joints being soldered near the valve must be done before connecting any
piping to the valve. Always leave at least 6" (152 mm) between the control valve and
joints being soldered when soldering pipes that are connected to the valve. Failure
to do this could cause damage to the valve.
The Flexx Oxi
-
Gen Water System is equipped with
1”
female pipe threaded ports on the
control valve bypass. The bypass is marked with arrows to show proper flow direction. The
arrow pointing toward the valve indicates the inlet. The arrow pointing away from the valve
is the outlet.
4.
Be sure to use Teflon tape or other pipe sealant on the plumbing fitting threads an in-
stall them in the bypass accordingly. Use channel locks to ensure they are tight.
NOTE:
All piping should be secured to prevent stress on the bypass valve and
connectors.