PROGRAMMING MODE
http://www.miwiurmet.com.pl e-mail:[email protected]
45
1 2 3 4
If logical user code for additional channel is not assigned, after
pressing the
button LED displays this communication:
L. L. L. L.
Enter logical user code for the main channel, confirm pressing the
button.
If logical user code for additional channel is already assigned,
confirm the old one or enter new code, then press the
button or
press
X
to delete.
SLAVE power supplier has to be programmed from its additional
keyboard.
MASTER power supplier can be programming from its additional or
any main keyboards
8.04 PROGRAMMING NUMBER OF KEYBOARD UNITING
LOGICAL ENTRY EXI WITH EO OF POWER SUPPLY IN
THE MAIN CHANNEL
Terminal EXI in the keyboard and EO in the power supplier is
defaulted used for opening door sensor.
P 8 0 4
In this step we are able to set the number of call module keyboard,
where by turning on terminal EXI, terminal EO also will be turned on
in the power supply.
We are able to set:
1 - 239 - number of selected keyboard,
0
- all keyboards,
255
- no keyboard.
In this step on LED appears dots.
To save new parameter please Press
button.
Default settings
- 0
8.05 PROGRAMMING NUMBER OF KEYBOARD FOR EI
TERMINAL IN THE POWER SUPPLY FOR THE MAIN CHANNEL
P 8 0 5
In this step we are able to set the number of call module keyboard,
by this module we can turn on relay exit NC-C-NO, if we turn on
terminal in the power supply ref. number which is serving this call
module.
We are able to set:
1 - 239 - number of selected keyboard,
0
- all keyboards,
255
- no keyboard.
In this step on LED appears dots.
To save new parameter press
button.
Default settings
- 0
9. FEATURES THAT IMPROVE
9.01 DEACTIVATION “OFF” INFORMATION
P 9 0 1
This step allows you to deactivate displaying “OFF” information in
case of lack called door phone. System are checking, whether door
phone is connected.
We are able to set:
0
- activate “OFF” information,
1
- deactivate “OFF” information
To save parameter press
button.
Default settings
- 0
9.02 MEASUREMENT THE CURRENT IN THE DOOR PHONE
LINE DURING CONVERSATION
P 9 0 2
This step allows measuring and displaying the current in the door
phone line during conversation (instead of logical user code)
We are able to set:
0
- display user code during conversation,
1
- display current value during conversation.
To save parameter press
button.
Default settings
- 0
9.03 PC CONNECTION CONFIGURATION
P 9 0 3
This step allows turning on monitoring function of RS232. If you set
parameter 1, thanks to RS232 interface you will be able to update
software and also monitor main and additional channel.
We are able to set:
0
- additional and main line monitor turn off,
1
- additional and main line monitor turn on.
To save parameter press
button.
Default settings
- 0
9.04 COMMUNICATION MODE IN THE MAIN CHANNEL
P 9 0 4
This step allows setting communication mode in the main channel.
We are able to set:
0
- normal mode,
1
- improving mode (more sensitive and stronger).
If you set improving mode, transmitter transmit with more power,
increase sensitive of receiver in the power supply. This mode is
recommended in harsh installation environment, for example with
influences and noises.
This steps is available only in 1052/33 suppliers.
To save parameter press
button.
Default settings
- 1
Содержание Miwi 1032/9
Страница 1: ...1 DIGITAL CALL SYSTEM...
Страница 2: ...http www miwiurmet com pl e mail miwi miwiurmet com pl 2...
Страница 4: ......
Страница 31: ...MOUNTING PANELS 1752 11 AND 1752 16 http www miwiurmet com pl e mail miwi miwiurmet com pl 31 Fig 9...
Страница 51: ...INSTALLATION http www miwiurmet com pl e mail miwi miwiurmet com pl 51...
Страница 79: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL http www miwiurmet com pl e mail miwi miwiurmet com pl 79...
Страница 81: ...DIAGRAMS THREE MAIN AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 81...
Страница 84: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 84...
Страница 86: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 86...
Страница 96: ...DIP SWITCH AND JUMPERS SETTINGS DIGITALIZER SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 96...
Страница 97: ...NOTES NOTES http www miwiurmet com pl e mail miwi miwiurmet com pl 97...