ERRORS REPORT
Call modules detect and identify lots of errors in Matibus SE
system. Communication about detected errors will be shown on the
LED display with correct code credited to specific error. Based on
this communication we are able to define what kind of problem
happened.
In the table below we present list of errors code with explanation.
E
r
0
1
Short-circuit in riser 1
E
r
0
2
Short-circuit in riser 2
E
r
0
3
Entering call code too slow
E
r
0
4
Logical user code has not been programmed
E
r
0
5
Incorrect open code
E
r
0
6
Line busy
E
r
0
7
Incorrect installer code
E
r
0
8
User code without assigned Dallas key
E
r
0
9
Incorrect physical code
E
r
1
0
Inactivity time too long (in programming
mode)
E
r
1
1
Several door phones with the same address
E
r
1
2
Dallas key already assigned
E
r
1
3
EEPROM full
-
-
-
-
Lack of communication between keyboard
and supplier, for example line D
disconnected
ADJUSTMENT CALL MODULES 1052/10../10D,
1052/11…/11D, 1052/15…/15D, 1052/16…/16D
Panel’s PCB is pre-adjusted during the manufacturing process.
Potentiometers "P1", "P2", "P3" allow adjustment of the panel,
however, should perform this step only if it is really necessary.
Function
P1
Adjusting the local effect
P2
Adjusting the call module speaker volume
P3
Adjusting the sensitivity of the microphone
J1 connector allows adjustment the electric lock current.
Jumpers
location
Value of current
Current of electrical lock around 150mA (work
with the reverse electrical lock)
Current of electrical lock around 300mA
Current of electrical lock around 600mA
1
0
*
#
9
8
7
6
5
4
2
3
P3
P2
P1
Содержание Miwi 1032/9
Страница 1: ...1 DIGITAL CALL SYSTEM...
Страница 2: ...http www miwiurmet com pl e mail miwi miwiurmet com pl 2...
Страница 4: ......
Страница 31: ...MOUNTING PANELS 1752 11 AND 1752 16 http www miwiurmet com pl e mail miwi miwiurmet com pl 31 Fig 9...
Страница 51: ...INSTALLATION http www miwiurmet com pl e mail miwi miwiurmet com pl 51...
Страница 79: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL http www miwiurmet com pl e mail miwi miwiurmet com pl 79...
Страница 81: ...DIAGRAMS THREE MAIN AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 81...
Страница 84: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 84...
Страница 86: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 86...
Страница 96: ...DIP SWITCH AND JUMPERS SETTINGS DIGITALIZER SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 96...
Страница 97: ...NOTES NOTES http www miwiurmet com pl e mail miwi miwiurmet com pl 97...