DIGITISER REF. 1052/7
PROGRAMMING
http://www.miwiurmet.com.pl e-mail:[email protected]
69
PROGRAMMING
ID SETTING
ID number is important in systems with several entrances. ID must
be unique for each call module (other digitisers and call modules
with keyboard).
Range of digitiser’s ID is 1 – 31. ID number is settings by ADRES
dip-switches.
1.
Use ADRES dip-switches 4-8 to set binary number of ID. Dip-
switch number 4 is the least significant bit. Other dip-switches
(1,2,3 and 9) must be set in OFF position.
2.
Press and hold for 3 seconds button PROG, until come on
green LED.
3.
If ID number is correct, call module generates confirmation
signal, green LED will be turned off. If ID will be not approved
(for example because of two the same ID number) call module
will generate warning signal, LED will start blinking for 3
seconds.
SETTINGS GROUP OF DIGITISERS
If entrance panel has more than 24 buttons, it is necessary to
create a group of digitisers. One Group consists of max. 4 digitisers
and can managed up to 96 buttons. Group can be supplied by one
power unit ref. 1052/31A or 1052/33. Voice and electrical lock are
condoled by “ZERO” digitiser.
Number of group is set by ADRES dip-switches 4-8, number ID of
digitiser in each group by dip-switches 1-2.
Table with dip-switches setting is on the end of this manual.
Dip-switch
settings
Group
ID
Binary
Description
2
16
Digitiser „zero” for 2
group
2
17
First Digitiser for 2
grup
2
18
Second Digitiser for
2 grup
2
19
Fourth Digitiser for
2 grup
10
145
First Digitiser for
10 grup
10
146
Second Digitiser for
10 grup
Digitiser “zero” can be replaced by call module with keyboard. This
solution allows you to assembly entrance panel with keyboard and
traditional buttons. Voice and electrical lock are served by call
module with keyboard. Call module with keyboard working as
digitiser “zero” must have ID from range 1-31.
Содержание Miwi 1032/9
Страница 1: ...1 DIGITAL CALL SYSTEM...
Страница 2: ...http www miwiurmet com pl e mail miwi miwiurmet com pl 2...
Страница 4: ......
Страница 31: ...MOUNTING PANELS 1752 11 AND 1752 16 http www miwiurmet com pl e mail miwi miwiurmet com pl 31 Fig 9...
Страница 51: ...INSTALLATION http www miwiurmet com pl e mail miwi miwiurmet com pl 51...
Страница 79: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL http www miwiurmet com pl e mail miwi miwiurmet com pl 79...
Страница 81: ...DIAGRAMS THREE MAIN AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 81...
Страница 84: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 84...
Страница 86: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 86...
Страница 96: ...DIP SWITCH AND JUMPERS SETTINGS DIGITALIZER SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 96...
Страница 97: ...NOTES NOTES http www miwiurmet com pl e mail miwi miwiurmet com pl 97...