DESCRIPTION OF TERMINAL BOARDS 

LG   

Voice line 

0L   

GND. 

D 

 

Data line. 

R 

 

Additional control terminal for video version 

GND 

Contacts input/output ground. 

+V   

Input voltage  + 15…+20 V DC. 

AC1  

Input voltage ~12 V AC. 

AC2  

Input voltage ~12 V AC. 

+CL  

Electric lock output (+). 

-CL   

Electric lock output (-). 

NC   

Relay normally closed contact. 

C 

 

Relay Common contact. 

NO   

Relay normally open contact. 

PH   

Door lock release. 

GND 

Contacts input/output ground. 

EXI   

Door sensor input. 

 
X1   

Microphone socket. 

X2   

Speaker socket. 

X12 

 Backlight  module  power  socket  (only  in  1052/11../11D  or 
1052/16../16D). 

X10  

Dallas key socket. 

 

BASIC SYSTEM FUNCTIONS 

1. 

Calling to all house phones, 

2. 

General and individual opening codes,  

3. 

Dallas key reader (only in 1052/15../15D and 1052/16../16D), 

4. 

Exit transmitter NC-O-NO controlled by general and individual 
opening codes and additional button in the house phone, 

5. 

Open door input. 

6. 

Exit dedicated to handling video, 

7. 

Hall button timed input, 

8. 

Programmable system, 

9. 

System information shown on LED display. 

 

SERIAL NUMBER OF CALL MODULE  

To see serial number of call module: 

-first  push  this  buttons  combination  0

2

#, 

then  you  will  see  less 

significant part of serial number. 
- press 

#

 to show the rest part of serial number. 

 

SERIAL NUMBER OF POWER SUPPLY  

To see serial number of power supply: 

- first push this button combination: 0

1

then you will see the less  

significant part of serial number of this power supply. 
- press 

#

 to show the rest part of serial number. 

 

RESET OF POWER SUPPLY 

To  reset  power  supply  please  push  this  button  combination 

0

666

#

.

 

To  reset  MASTER  power  supply,  push  this  button 

combination in call module connected to the main channel. 
 

EMERGENCY ENTER TO THE PROGRAMMING MODE 

If  the  entering  password  is  unknown,  we  are  able  to  enter  to  the 
programming mode by pressing two buttons- first SW1 button which 
is located on PCB board inside the panel and after this function we 

have  got  maximum  2  seconds  time  to  press 

∗∗∗∗

  button  on  the 

keyboard. 
 
 

OPERATION INSTRUCTION 

DEFAULT SETTINGS OF USER CODES 

Power  supply  is  default  programmed  for  the  first  50  user  codes  in 
the  first  riser.  Default,  first  riser  handle  user  codes  in  range  1-50, 
but  system  is  able  to  generate  255  user  codes  automatically. 
Number of user codes can be increase by changing parameters in 
programming  mode.  In  order  to  increase  number  of  user  codes 
automatically,  change  parameters  in  steps  7.4  and  7.5,  and 
generate new individual opening user codes by step 4.4 . 
    

SIGNALING OF DOOR LOCK AND NO-NC RELEASING  

If  the  door  lock  or  NO-C-NC  relay  is  releasing,  call  module  emits 
beeps and on display appears rotating dashes. 

 

CALL TO USERS 

Each user of the Matibus SE system can be called by entering the 
appropriate  number.  The  personal  user  code  can  compose  of 
numbers  from  1  to  4  long  and  in  range  from  1……9999.  These 
users’  codes  (logic  codes)  are  associated  with  the  house  phones 
codes  (physical  codes).  Every  house  phone  has  unique  code 
depending of the number of riser and of

 the 

setting the jumpers in 

house  phone.  In  Matibus  SE  system  is  possible  that  two  house 
phones can work in  parallel.

 

 
After  entering  the  correct  user  code  we  can  wait  3  s  and  the  call 
connection will be initiated automatically, or press the 

#

 button and 

connect straight away.  

If  we  made  a  mistake  please  press 

∗∗∗∗

  and  this  will  delete  previous 

number. 

 

Called  house  phone  will  ring  as  long  as  it  was  programmed. 
The programmable time is from 1s to 30 s. The answering time 
is also programmable in the same range what ringing time from 
1 s to 30 s. Pickup time signaled is a recurrent dual signal calls 
(option is on) 

 

Conversation  is  possible  when  we  picked  up  the  handest. 
During  the  conversation  we  can  open  the  door  by  pressing 
dedicated  button  for  this  function.  After  pressed  the  button  in 
the receiver will be played short signal to confirm this function. 
The electric lock will be open as long as we programmed it, the 
range of this time is from 1s to 30s. 

 
Maximum time of conversation is from 30s to 120s, after that time in 
the  receiver  will  be  played  signal  to  warn  that  the  conversation  is 
nearly over, and after it, the conversation will be disconnected. 
 

GENERAL OPENING CODES IN USE 

We are able to open door using 1 from 64 general 4 digits opening 
codes. To do it: 

 

Press 

# 

button,

 

 

Enter  1  of  64  general  4  digital  opening  code,  for  example: 
1234,

 

 

Confirm by pressing 

#

 button.

 

General opening code can be turned off in a programming mode. 

 

INDIVIDUAL OPENING CODES IN USE 

We  are  able  to  open  door  using  1  of  the  individual  opening  code. 
This  code  is  4  digits.  To  open  door  with  this  code  first  we  have  to 
enter logical user code and than individual opening code which was 
associated with each other. Individual opening code can be from 5 
to 8 digits.  

 

Press 

#

 button,

 

 

Enter individual opening code – from 5 to 8 digits (logical user 
code + 4 digits combination code),

 

 

Confirm by pressing 

# 

button. 

 

Содержание Miwi 1032/9

Страница 1: ...1 DIGITAL CALL SYSTEM...

Страница 2: ...http www miwiurmet com pl e mail miwi miwiurmet com pl 2...

Страница 3: ...31 520 52 HOUSE PHONE WITH ADDITIONAL BUTTON REF 1131 521 53 TABLE TOP MOUNTING KIT REF 1130 120 53 HOUSE PHONE REF 1132 520 54 HOUSE PHONE WITH ADDITIONAL BUTTON REF 1131 521 55 TABLE TOP MOUNTING KI...

Страница 4: ......

Страница 5: ...y and ventilated places it is recommended that it is assembled in special boxes designed for this purpose Equipment should be separated from the electrical telephone and antenna installations WIRES A...

Страница 6: ...onnection one entrance panel and max 510 door phones using two risers in the power unit INSTALATION WITH SEVERAL MAIN ENTRANCE PANELS Connection up to 240 entrance panels and max 510 door phones using...

Страница 7: ...ANEL Connection one entrance panel and max 127 video door phones using one riser in the power unit or 254 video doorphones using two risers in the power unit VIDEO DOORPHONE INSTALATION WITH SEVERAL E...

Страница 8: ...x width x deep 152 x 110 x 23 35mm ref no 1052 10D Size high x width x deep 175 x 135 x 23 6mm with frame 525 RP2 CALL MODULE WITH KEYBOARD REF 1052 11 11D BASIC FEATURES Digital call module with keyb...

Страница 9: ...width x deep 152 x 110 x 23 35mm ref no 1052 10D Size high x width x deep 175 x 135 x 23 6mm with frame 525 RP2 CALL MODULE WITH KEYBOARD REF 1052 16 16D BASIC FEATURES Digital call module with keyboa...

Страница 10: ...e In order to increase number of user codes automatically change parameters in steps 7 4 and 7 5 and generate new individual opening user codes by step 4 4 SIGNALING OF DOOR LOCK AND NO NC RELEASING I...

Страница 11: ...a button which performs this function FUNCTION OF TERMINAL R The Matibus SE call module is equipped with terminal R which is output in the form of open collector From the start of conversation till t...

Страница 12: ...6 Call module software version P 7 X X Advanced functions 0 0 Keyboard backlight adjustment 0 1 Switch on switchboard 0 2 Programming number of keyboard uniting logical entry EXI with EO of power supp...

Страница 13: ...the house phone when individual opening code associated with that house phone was used We can choose 0 Turn off confirmation of opening the door and exit NC C NO 1 Turn on confirmation of opening the...

Страница 14: ...or phone line 1 7V door phone line To save entered changes press Default settings 1 2 TIME SETTINGS 2 01 ELECTRICAL LOCK TIME OF WORKING P 2 0 1 After pressed the button on the LED display will be sho...

Страница 15: ...be shown this communication 3 04 DELETING ALL LOGICAL USER CODE MASTER P 3 0 4 To activate this function please press button During this process on LED display will be shown this communication 3 05 D...

Страница 16: ...store times Advanced functions To activate this function please press button During this process on LED display will be shown this communication 5 LOGICAL USER AND OPENING CODES 5 01 LOGICAL USER CODE...

Страница 17: ...ation o o o o If logical code is already associated with some opening code this opening code will be shown on the LED display Than you should Enter 4 digits number of new code or leave previous one Co...

Страница 18: ...key or press button to exit 5 07 DALLAS KEY IDENTIFICATION This step allows you to identify Dallas key P 5 0 7 Pressing the button on the LED will be shown this communication In order to identify Dall...

Страница 19: ...creen will be shown less significant part of the software version for example software for call module serial number of software 0718 the LED display will show L 7 1 8 Another pressing the button will...

Страница 20: ...s connected to call module by terminals CL CL These terminals are able to service electric door lock for DC and AC voltage Parameter which we will choose in this part of the programming mode set the f...

Страница 21: ...ical code of the house phone Confirm by pressing button If the physical code was not associated with any logical user code the LED displays this communication L L L L If physical code has been already...

Страница 22: ...LED appears dots To save new parameter press button Default settings 0 9 FEATURES THAT IMPROVE 9 01 DEACTIVATION OFF INFORMATION P 9 0 1 This step allows you to deactivate displaying OFF information i...

Страница 23: ...exing additional ringback tone on the house phone while waiting for pick up the handy pickup time We are able to set 0 OFF 1 ON Press button to save parameter Default settings 1 9 07 AUTOMATIC CHOOSIN...

Страница 24: ...ct physical code E r 1 0 Inactivity time too long in programming mode E r 1 1 Several door phones with the same address E r 1 2 Dallas key already assigned E r 1 3 EEPROM full Lack of communication be...

Страница 25: ...light on the LED display should appear blinking dot In case of lack of backlight check connection and installation check terminal voltage AC1 and AC2 Communication checking The best way to check commu...

Страница 26: ...of the case 8 Press down part of the PCB assembly kit 9 Connect the wires 10 Connect terminal X2 speaker and X10 Dallas key reader Fig 2 11 Close and fasten the front panel Fig 2 PCB assembly kit FLU...

Страница 27: ...ssembly kit into latches located in the top part of the case 11 Press down part of the PCB assembly kit 12 Connect the wires 13 Connect terminal X2 speaker X10 Dallas key reader and X12 backlight info...

Страница 28: ...klight information module It enables you to put a list of tenants This panel is characterized by a high degree of protection from acts of vandalism CALL MODULE WITH KEYBOARD AND CAMERA REF 1752 16 16D...

Страница 29: ...V AC CL Electric lock output CL Electric lock output NC Relay normally closed contact C Relay Common contact NO Relay normally open contact PH Door lock release GND Contacts input output ground EXI Co...

Страница 30: ...it into latches located in the top part of the case 11 Press down part of the PCB assembly kit 12 Connect the wires 13 Connect terminal X2 speaker X10 Dallas key reader and X12 backlight information p...

Страница 31: ...MOUNTING PANELS 1752 11 AND 1752 16 http www miwiurmet com pl e mail miwi miwiurmet com pl 31 Fig 9...

Страница 32: ...utton in the house phone 5 Open door input 6 Exit dedicated to handling video 7 Hall button timed input 8 Programmable system 9 System information shown on LED display STRUCTURE Call module is based o...

Страница 33: ...to 4 long and in range from 1 9999 These users codes logic codes are associated with the house phones codes physical codes Every house phone has unique code depending of the number of riser and of th...

Страница 34: ...terminal PH which is performing for local opening door Connection PH and GND lead to turn on electric lock for programmed time To implement this function during the installation between terminals PH...

Страница 35: ...ll module software version P 7 X X Advanced functions 0 0 Keyboard backlight adjustment 0 1 Switch on switchboard 0 2 Programming number of keyboard uniting logical entry EXI with EO of power supply i...

Страница 36: ...n the house phone when individual opening code associated with that house phone was used We can choose 0 Turn off confirmation of opening the door and exit NC C NO 1 Turn on confirmation of opening th...

Страница 37: ...ORKING P 2 0 1 After pressed the button on the LED display will be shown actual programmed time in seconds To confirm that time press button or enter number of seconds from 1 to 30s To save entered ch...

Страница 38: ...LL DALLAS KEYS P 3 0 5 To activate this function please press button During this process on LED display will be shown this communication 3 06 DELETING ALL DIGITISER DATA P 3 0 6 To activate this funct...

Страница 39: ...gic user code can be associated to every physicla user code set in the house phone physical code To do it Enter the number of riser to which house phone is connected Enter physical code of the house p...

Страница 40: ...G P 5 0 4 You can program 64 general opening codes with the possibility of individual assignment to specific keyboard The maximum number of codes is constant for the MASTER power supply which means in...

Страница 41: ...generate warning signal Press button to exit 6 SERVICE FUNCTIONS 6 01 SERIAL NUMBER OF THE POWE SUPPLY P 6 0 1 Entering in to this function we are able to get known serial number of the Power supply s...

Страница 42: ...y will show L 7 1 8 Another pressing the button will shown the rest part of the version of software for call module serial number of software 0718 the LED display will show H 0 7 ADVANCED FUNCTIONS 7...

Страница 43: ...his step we are programming frequency of electric door lock mode which is connected to call module by terminals CL CL These terminals are able to service electric door lock for DC and AC voltage Param...

Страница 44: ...umpers set in the house phone physical code To do it Enter the number of riser to which house phone is connected Enter physical code of the house phone Confirm by pressing the button If the physical c...

Страница 45: ...oards 255 no keyboard In this step on LED appears dots To save new parameter press button Default settings 0 9 FEATURES THAT IMPROVE 9 01 DEACTIVATION OFF INFORMATION P 9 0 1 This step allows you to d...

Страница 46: ...tone on the house phone while waiting for pick up the handy pickup time We are able to set 0 OFF 1 ON Press button to save parameter Default settings 1 9 07 AUTOMATIC CHOOSING OF MASTER POWER SUPPLY...

Страница 47: ...without assigned Dallas key E r 0 9 Incorrect physical code E r 1 0 Inactivity time too long in programming mode E r 1 1 Several door phones with the same address E r 1 2 Dallas key already assigned E...

Страница 48: ...ght on the LED display should appear blinking dot In case of lack of backlight check connection and installation check terminal voltage AC1 and AC2 Communication checking The best way to check communi...

Страница 49: ...height of approximately 1 55 1 60 meters Important The module should not be illuminated from behind to make the calling module display easier to read Never direct the module towards strong sources of...

Страница 50: ...rame screw last FLUSH MOUNTED VERSION WITH RAIN HOOD Rain hoods are used to protect the calling module from the weather Embed the flush mounting box in the wall position the waterproof hood and fasten...

Страница 51: ...INSTALLATION http www miwiurmet com pl e mail miwi miwiurmet com pl 51...

Страница 52: ...mber 1 We use only first 8 jumpers from right and the other two are used for testing house phone Number of house phone is set in binary code as described on the PCB Each jumper founded increases the n...

Страница 53: ...itting other 3 supplementary buttons Additional button can be used for calling switchboard control NO NC relay etc Additional button is connected with terminals T1 and L and serves to control power su...

Страница 54: ...1 We use only first 8 jumpers from right and the other two are used for testing house phone Number of house phone is set in binary code as described on the PCB Each jumper founded increases the numbe...

Страница 55: ...fitting other 6 supplementary buttons Additional button can be used for calling switchboard control NO NC relay etc Additional button is connected with terminals T1 and L and serves to control power s...

Страница 56: ...physical address is set with jumpers We can set the phone number from 1 to 255 The first jumper from right is the number 1 We use only first 8 jumpers from right and the other two are used for testin...

Страница 57: ...rovided with additional button and ready for fitting other 6 supplementary buttons Additional button can be used for calling switchboard control NO NC relay etc Additional button is connected with ter...

Страница 58: ...an be installed on the wall without the need of forging the wall The Winflat has adjustable call tone volume brightness and contrast The Winflat is provided with 2 supplementary buttons for activating...

Страница 59: ...F button implement video auto on function S3 button configuration Service button active Floor call terminals Y1 Y2 active S4 button configuration Service button active UTP S5 Kind of video line COAX P...

Страница 60: ...ut for external bell push Connection Y1 and Y2 together will be activated floor call ring in the video door phone SELECTING CALLING TONE The bracket is equipped with 3 calling tones To select calling...

Страница 61: ...ND EI Entry control relay or electrical lock 0L GND for riser 2 LU2 Riser 2 0L GND for riser 1 LU1 Riser 1 DIAGNOSTIC Two LED indicate the status of the power supply The illumination of a green LED in...

Страница 62: ...door output 0L GND EI Entry control relay or electrical lock 0L GND for riser 2 LU2 Riser 2 0L GND for riser 1 LU1 Riser 1 DIAGNOSTIC Two LEDs indicate the status of the power supply The illumination...

Страница 63: ...AC Power 20 VA Output voltage 0 20 20 V DC 0 8 A max Operating temperature 5 C 45 C Protectio Fuse 100mA Dimensions Length 126 mm 7 DIN Width 90 mm Deep 75 mm VIDEO POWER SUPPLY REF 789 7P BASIC FEAT...

Страница 64: ...butor 1 Press PROG button 2 Red LED will turn on 3 Make a call to one of the monitor connected to relevant distributor 4 Wait until camera s image appears and disconnect conversation One of the distri...

Страница 65: ...vided with 4 independent outputs plus one through output DESCRIPTION OF TERMINALS R1 Power input gnd R2 Power input positive E Coax input U1 U5 Coax output Remove jumper JP1 in the video distributor t...

Страница 66: ...equipped with 4 relay outputs one of them is dedicated for COAX cable DESCRIPTION OF TERMINALS Ra Relay control input Rb Relay control input 12 Power voltage 12 V DC 24 Power voltage 24 V DC 12V 24V...

Страница 67: ..._4 OUTPUT_1 3 For example Dipswitches 2 and 3 set to ON number 6 Physical address for first output will be 6 4 3 21 Physical address for 2nd output will be 22 Physical address for 3rd output will be 2...

Страница 68: ...Speaker GL2 Speaker GND Microphone GND 441 Microphone G8 8 level of buttons G7 7 level of buttons G6 6 level of buttons G5 5 level of buttons G4 4 level of buttons G3 3 level of buttons G2 2 level of...

Страница 69: ...GS GROUP OF DIGITISERS If entrance panel has more than 24 buttons it is necessary to create a group of digitisers One Group consists of max 4 digitisers and can managed up to 96 buttons Group can be s...

Страница 70: ...tion To program door phone connect to the other power unit exit the programming mode first and start from the beginning setting new number of power unit 7 Press button PROG for 3 seconds to exit Dipsw...

Страница 71: ...L GND 5 GND GND RS232 is used for connection switchboard with PC for example for download user s repertory or update the software PIN Mark Description 1 GND GND 2 RX in RS232 input 3 TX out RS232 outp...

Страница 72: ...UPPLY ID Enter number of power supply connected to relevant panel and press to confirm If panel is connected to the main channel main entrance just press The following will appear ENTRANCE PANEL ID En...

Страница 73: ...d press to confirm NO ACTION Relay will be not activated by any events 3 TIME SETTINGS In the stand by mode switchboard station shows actually time and data This function is used also for automaticall...

Страница 74: ...estore default settings of the switchboard station The following will appear DEFAULT SETTINGS RESTORE Press to exit Press to confirm The following will appear WAIT Default settings will be restoring i...

Страница 75: ...y on display appears number of event with time and data LED next to button switches on 19 10 2007 20 53 EVENT 1 Conversation can be disconnected by pressing button on the call module keyboard or by ha...

Страница 76: ...tch on night mode is indicated by lighting up LED next to button Automatic change from day to night mode is also indicated by lighting up LED next to button In the night service all calls from entranc...

Страница 77: ...1001 Press to confirm an old one To change logical user code press to delete old one enter new logical user code and confirm by pressing The following will appear NAME KOWALSKI You can confirm old na...

Страница 78: ...tchboard and main channel propably line D disconnected LACK OF DOOR PHONE Attempt to call disconnected door phone NO ANSWER User does not pick up the call ADJUSTMENT The switchboard station is pre adj...

Страница 79: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL http www miwiurmet com pl e mail miwi miwiurmet com pl 79...

Страница 80: ...DIAGRAMS ONE MAIN AUDIO ENTRANCE PANEL EXTENDED VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 80...

Страница 81: ...DIAGRAMS THREE MAIN AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 81...

Страница 82: ...DIAGRAMS ONE MAIN AND THREE ADDITIONAL AUDIO ENTRANCE PANELS http www miwiurmet com pl e mail miwi miwiurmet com pl 82...

Страница 83: ...DIAGRAMS MASTER SLAVE STRUCTURE WITH SWITCHBOARD STATION http www miwiurmet com pl e mail miwi miwiurmet com pl 83...

Страница 84: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 84...

Страница 85: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL COAX VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 85...

Страница 86: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION http www miwiurmet com pl e mail miwi miwiurmet com pl 86...

Страница 87: ...DIAGRAMS ONE VIDEO ENTRANCE PANEL UTP VERSION WITH DISTRIBUTORS REF 1752 54 http www miwiurmet com pl e mail miwi miwiurmet com pl 87...

Страница 88: ...DIAGRAMS THREE VIDEO ENTRANCE PANELS UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 88...

Страница 89: ...DIAGRAMS DECODER REF 1052 34 UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 89...

Страница 90: ...DIAGRAMS DECODER REF 1052 34 UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 90...

Страница 91: ...DIAGRAMS DECODER REF 1052 34 UTP VERSION WITH DISTRIBUTORS http www miwiurmet com pl e mail miwi miwiurmet com pl 91...

Страница 92: ...DIAGRAMS ONE ANALOGUE ENTRANCE PANEL SYSTEM WITH DIGITALIZER http www miwiurmet com pl e mail miwi miwiurmet com pl 92...

Страница 93: ...DIAGRAMS THREE ANALOGUE ENTRANCE PANELS SYSTEM WITH DIGITALIZERS http www miwiurmet com pl e mail miwi miwiurmet com pl 93...

Страница 94: ...DIP SWITCH AND JUMPERS SETTINGS TABLE OF VIDEO BRACKET SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 94...

Страница 95: ...DIP SWITCH AND JUMPERS SETTINGS TABLE OF DOOR PHONE SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 95...

Страница 96: ...DIP SWITCH AND JUMPERS SETTINGS DIGITALIZER SETTINGS http www miwiurmet com pl e mail miwi miwiurmet com pl 96...

Страница 97: ...NOTES NOTES http www miwiurmet com pl e mail miwi miwiurmet com pl 97...

Страница 98: ...98 MIWI URMET Co Ltd ul Pojezierska 90A 90 341 Lodz Poland tel 004842 616 21 00 fax 004842 616 21 12 http www miwiurmet com pl e mail miwi miwiurmet com pl...

Отзывы: