23. Press key
▼
until “FUNCTION KEYS” appears. Press
OK
key and use keys
▼
and
▲
to
enable or disable function keys “Fire”, “Silent panic” and “Emergency” (see § 5.3),
confirming choices by
OK
key.
24. Program the other keypads by following the same procedure from step 7; otherwise, press
ESC
repeatedly to exit from the menu.
4.9 READERS
PROGRAMMING
Following programming is provided for readers:
•
Association to Zones
: the LEDs of each key reader can be freely associated to one or more System zones.
It is not possible to associate the same zone to more LEDs of the same key reader.
The key reader operates on zones associated to its 3 LEDs:
- total arm performed from that key reader corresponds to the arm of all zones associated to that key reader;
- every green LED displays the status of associated zones (see § 2.2);
- through yellow LED, only open inputs and alarms concerning associated zones are displayed.
•
Masking
: masking allows to enable the masking of system status on the reader (see § 5.2.8). Masking inhibits key
reader LED signalling, which will only become visible at inserting a valid key.
To program an electronic or proximity key reader, access, from Technician menu «PROGRAMMING» / «READERS».
Then select the number of reader to be programmed.
Reader submenu is then accessed where there can be configured:
•
«ASSIGN
»
o
«LED 1»
to associate reader LED 1 to zones
o
«LED 2»
to associate reader LED 2 to zones
o
«LED 3»
to associate reader LED 3 to zones
Close to LED numbering there is graphically indicated LED position on key reader.
□
= not associated zone
■
= associated zone
By keys
◄
and
►
you can move through zones; you can either associate or not associate the zone you are positioned
on by pressing keys
▼
and
▲
. At the end, press
OK
key to confirm; the system will associate the key reader to
preselected zones.
•
«MASKING» choose whether enable or disable system status masking on reader.
•
« NAME »
you can give a description name max 24 characters long to connector (see § 4.2).
4.10 RADIO DEVICES PROGRAMMING
Like previously described for wired devices as concerns input and output programming, radio device programming too is
modelled on the same architecture, to which have been added specific menus relevant to radio devices and remote
control. Below, the programming menu flowchart, already present in 1067, control panel, shows the plug-in level from
the new branch, improved with all the parameters that can be selected on each peripheral:
NOTE:
function available with 1067 control panel and 1067/021 keypads, software version 3.00 or higher and with an
1067/010 radio expansion.
KP01:KP 01
FUNCTION KEYS
FUNCTION KEYS
FIRE
INSTALLER
MAINTENANCE
TEST
ACQUIRE
DELETE
RADIO DEVICES
ACQUIRE
CONFIGURATION
DELETE
SELECT EW 01
SELECT
ACQUIRE
INPUT DEVICES
SELECT
ACQUIRE
OUTPUT DEVICES
ACQUIRE
IR/DC/RC IN PROGESS
ACQUIRE SIRENS
IN PROGESS
SELECT EW 01
SELECT IR
SELECT DC
SELECT RC
SELECT SIR
SELECT EW 01
DELETE IR
DELETE DC
DELETE RC
DELETE SIR
SUPERVISION
JAMMING
BATTERY
TEST INPUTS
TEST OUTPUTS
ADVANCED