16
Maintenance And Service
c
omPonent
a
ccess
:
1. Remove the safety screen (see
M
aIntenance
a
nD
s
erVIce
- r
eMoVe
s
afety
s
creen
on page 10).
2. Remove the door trim (see
M
aIntenance
a
nD
s
erVIce
- r
eMoVe
D
oor
t
rIM
on page 11).
3. Remove the glass door (see
M
aIntenance
anD
s
erVIce
- G
lass
D
oor
r
eMoVal
on page 11).
4.
Remove light deflector (see Figure 15).
5. Remove the front steel liner (see Figure 21).
6. The components can be accessed behind the right
liner panel. Loosen the two (2) bolts on the right liner
retainer using a 5/16” socket until it can be removed.
See Figure 22.
Loosen
F
use
R
ePLacement
:
1. Disconnect electrical power to the unit.
2. Remove component backpack (see
M
aIntenance
anD
s
erVIce
- c
oMPonent
B
ackPack
r
eMoVal
on page 13). If the
unit is already framed into the wall, refer to
M
aIntenance
anD
s
erVIce
- c
oMPonent
a
ccess
a
fter
I
nstallatIon
on page 15.
3. Remove the fuse cover by removing the two
T-20 screws (see Figure 20).
4. Remove the fuse by removing the two T-20
screws if they appear damaged.
5. Reconnect power to the unit.
Figure 20: Fuse Removal
Figure 21: Front Steel Liner Removal
Figure 22: Liner Retainer Removal
Figure 23: Right Liner Removal
7.
Remove the right liner from the firebox. See Figure 23.
8.
Using a T-20 screwdriver remove the 12 screws from the black cover plate on the firebox side to gain access
to the valve, IFC, and fuse.