29
Initial Installation
QUALIFIED INSTALLERS ONLY
R
ecess
i
nstaLLation
These are the minimum allowable dimensions required to safely operate the appliance. Plan your entire
installation before proceeding. The maximum allowable framed depth for a recess is 3 1/2” (90mm).
Figure 51: Recess Installation
44 1/2”
Framed
Opening
Height
79 1/2”
Minimum
Ceiling
†
46 1/4" Framing Width
3 1/2" Max. Framed
Recess Depth
4 3/4" Min.
Ceiling to Elbow
Clearance
Adjustable Framing Depth
24 1/4” [1/2” Facing Mat.] - 22 3/4" [2" Facing Mat.]
30" Min.
Overhang / Soffit
Clearance
Sidewall Clearance In Front of
Fireplace = 3 1/2” from Tiling Edge
1 OF 1
SHEET
Part Description
DATE
GENERAL TOLERANCE: +/- 1/32”
Urbana Luxury Fireplaces
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS IN INCHES
DRAWN BY
THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.
JM
U37 Framing & Clearances
08/06/21
REV
SCALE - NOT TO SCALE
Termination Sidewall
Clearance = 7"
1”- 4” Mantle
Clearance = 6"
*Clearance reduced to 0” if
installed with CSS activated*
12” Non-Combustible
Facing Zone
*Combustible facing
permitted if installed
with CSS activated*
32 5/8”
Finishing
Height
37 5/8” Finishing Width
Min Vent [8x11] =
2' up + 90˚
Elbow
69 7/16” Thimble
(center of pipe)
†
†
Dependent on brand of 8x11 venting used. Additional
3” required if using Metal-Fab Sure-Seal
†
Option 5: No Visible Discharge w/ Chase Comfort Kit (50-4175)
- If use of the CSS system is
desired/required but a visible discharge is not wanted anywhere then the Chase Comfort Kit may be used.
The Chase Comfort Kit is a blower motor housing that gets mounted on the same exterior wall as the chase
and discharges the heat outside. The Comfort Kit will always be in operation whenever the fireplace is on
and the blower speed is non-adjustable. For more details and installation specifications refer to the 50-4175
Chase Comfort Kit manual.