background image

3

Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “Urbana” Appliance, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All  Urbana  gas-fired  appliances  must  be  installed  in 

accordance with their instructions. Carefully read all the 

instructions  in  this  manual  first.  Consult  the  building 

authority having jurisdiction to determine the need for a 

permit prior to commencing the installation.
•  NOTE: Failure to follow these instructions could cause 

a malfunction of the fireplace, which could result in death, 

serious bodily injury, and/or property damage.
• Failure to follow these instructions may also void your 

fire insurance and/or warranty.

GENERAL

•  Installation  and  repair  should  be  done  by  a  qualified 

service person. The appliance should be inspected before 

the first use and, at least, annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding material, etc.  It 

is imperative the control compartments, burners and 

circulating air passageways of the appliance be kept 

clean.
• Due to high temperatures, the appliance should be 

located out of high traffic areas and away from furniture 

and draperies.
Children and adults should be alerted to the 

hazards of high surface temperatures and should 

stay away to avoid burn or clothing ignition.
• Young children should be carefully supervised when in 

the same room as the appliance.  Toddlers, young children 

and others may be susceptible to accidental contact 

burns.  A physical barrier is required if there is a risk for 

individuals in the house.  To restrict access to a fireplace 

or stove install an adjustable safety gate to keep toddlers, 

young children and other at risk individuals out of the 

room and away from hot surfaces. Any safety screen, 

guard, or barrier removed for servicing an appliance must 

be replaced prior to operating the appliance.

•  Clothing  or  other  flammable  materials  should  not  be 

placed on or near the appliance.

• A barrier designed to reduce the risk of burns from the 

hot viewing glass is provided with this appliance and shall 

be installed for the protection of children and other at-risk 

individuals. If the barrier becomes damaged, the barrier 

shall be replaced with the manufacturer’s barrier for this 

appliance.
FOR YOUR SAFETY

• Installation and service must be performed by a qualified 

installer, service agency or gas supplier.
• This installation must conform to local codes or, in the 

absence  of  local  codes,  with  the  National  Fuel  Gas  Code, 

ANSI Z223.1/NFPA 54, or the Natural Gas and Propane 

Installation Code, CSA B149.1.

• To prevent injury, do not allow anyone who is unfamiliar 

with the stove to operate it.
 To prevent injury, if the pilot or pilot and burners 

have gone out on their own, open the glass door and 

wait 5 minutes to air out before attempting to re-

light the stove.
• Always keep the area around these appliances clear of 

combustible material, gasoline and other flammable liquids 

and vapours.
• These appliances should not be used as a drying rack for 

clothing or for hanging Christmas stockings/decorations.

• Due to the paint curing on the stove, a faint odor and slight 

smoking will likely be noticed when the stove is first used.  

Open a window until the smoking stops.
Always connect this gas stove to a vent system and vent to 

the outside of the building envelope. Never vent to another 

room  or  inside  the  building.  Make  sure  the  specified  vent 

pipe is used, properly sized and of adequate height to 

provide sufficient draft.  Inspect the venting system annually 

for blockage and signs of deterioration.
WARNING:  Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts specifically approved with this appliance, may result in 

property damage or personal injury.
WARNING: Do not operate with the glass front removed, 

cracked or broken.  Replacement of the glass should be done 

by a licensed or qualified service person.

• Never use solid fuels such as wood, paper, cardboard, coal, 

or any flammable liquids, etc., in this appliance.

• Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control  system or 

any gas control which has been under water.
• Do not abuse the glass by striking it or slamming the door 

shut.
• If the U37I unit is pulled out of its installation, and the vent-

air intake system is disconnected for any reason, ensure that 

the vent-air intake pipes are reconnected and re-sealed in 

accordance to the instructions noted in 

I

nItIal

 I

nstallatIon

 

- D

Irect

 V

ent

HOT GLASS 

WILL 

CAUSE BURNS

DO NOT TOUCH 

GLASS 

UNTIL COOLED. 

NEVER

 ALLOW CHILDREN

TO TOUCH GLASS. 



A barrier designed to reduce the risk of burns from the

hot viewing glass is provided with this appliance and must 

individuals.

Содержание U37I

Страница 1: ...ITUDES WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be perform...

Страница 2: ...immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service m...

Страница 3: ...be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54...

Страница 4: ...al 12 Burner Shutter Cap Adjustment 13 Component Backpack Removal 13 Top Light Replacement 14 Component Access After Installation 15 Fuse Replacement 16 Burner Conversion 5 x 8 Venting 17 Fuel Convers...

Страница 5: ...42 Allowable Snorkel Installation 5 x 8 44 Allowable Co Axial Vent Configurations 8 x 11 44 Exhaust Restrictor Setting 45 Horizontal Termination 46 Vertical Termination 47 Gas Line Connection and Test...

Страница 6: ...IANCES CSA 2 17 GAS FIRED APPLIANCES FOR HIGH ALTITUDES This Urbana U37I U37I A Decorative Appliance Is not a source of heat Has been certified for use with either natural gas or propane see rating la...

Страница 7: ...4 1 4 616 24 7 8 632 22 1 4 565 22 3 8 568 8 x 11 Vent Remove the safety screen to access the rating label and lighting instructions They are attached to a length of chain and are never to be tampered...

Страница 8: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only the remote supplied with this fireplace...

Страница 9: ...Service Surround Panel Removal and Maintenance And Service Glass Door Removal Check the gasket material on the back of the glass making sure that it is attached and intact During a cold start up cond...

Страница 10: ...silicone around the perimeter of the door and install the new piece of glass with gasket Apply even pressure to the glass to allow the silicone to adhere to the gasket material Cleaning Decorative Su...

Страница 11: ...l they lock into place see Figure 7 WARNING Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fireplace with the glass door removed Fig...

Страница 12: ...r assembly see Figure 10 8 Remove the two 2 T 20 screws securing the orifice mount clamp onto the burner see Figure 11 9 Loosen the two 2 T 20 screws securing the burner to the firebox see Figure 12 T...

Страница 13: ...e the backpack and access the components remove the eight 8 T 20 screws around the perimeter see Figure 14 Once installed the components can be accessed from inside the firebox Refer to Maintenance An...

Страница 14: ...ect them from the bulb assembly Remove assembly from unit then disconnect the ground wire Figure 15 Light Deflector Removal Figure 16 Top Light Removal Top Light Cover Light Gasket Light Retainer Top...

Страница 15: ...Manifold Pressure Tap Power Vent Switch IFC Reset Burner Switch Backup Batteries Figure 19 Control Panel For convenience the fireplace comes pre wired for power vent applications If needed to switch...

Страница 16: ...Replacement 1 Disconnect electrical power to the unit 2 Remove component backpack see Maintenance and Service Component Backpack Removal on page 13 If the unit is already framed into the wall refer to...

Страница 17: ...all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may resul...

Страница 18: ...ce and Service section of Owner s Manual 9 Purge any air from gas line and reconnect to unit 10 Use a small brush and apply a warm soapy water solution to all gas connections If a gas leak is present...

Страница 19: ...abel to signify that the unit has been converted to a different fuel type Introduction This section of the owner s manual is for the use of qualified technicians only There are several installation sa...

Страница 20: ...hape Figure 32 Top Standoff Install Top Standoffs Initial Installation QUALIFIED INSTALLERS ONLY 3 Install heat shield support using four 4 supplied T 20 screws see Figure 33 Figure 33 Top Standoff Su...

Страница 21: ...ll if CSS has been activated To install the optional finishing edges 1 Remove the safety screen see Maintenance And Service Remove Safety Screen on page 10 2 Use a T 20 Screwdriver to remove the exist...

Страница 22: ...re two side covers attached via magnets Gently pull on the side cover until they detach and set them aside see Figure 36 4 There are thirteen 13 slotted fasteners that need to be loosened to adjust th...

Страница 23: ...ol Surface System CSS has been correctly activated allowing heat in the chase to be vented This system keeps the front wall cool enough for any combustible materials The supplied non combustible board...

Страница 24: ...view the guidelines in the previous sections to ensure your install is in accordance with the framing specifications Follow these instructions to activate the CSS feature Step 1 Remove the safety scre...

Страница 25: ...yered on top of the supplied Non combustible board Supplied board not needed for thick non combustible finishes like rock Cool Surface System Extended Install By adjusting the cabinet back combustible...

Страница 26: ...finish the CSS IMPORTANT When using 5 x 8 venting the CSS MUST BE ACTIVATED prior to installation Use of 5 x 8 venting is NOT PERMITTED without the CSS activated Figure 42 Framing Option 1 Initial In...

Страница 27: ...em when using combustible materials Consider Option 3 Valance to work in conjunction with this option 2 MIN 3 2 51mm Minimum 121mm Minimum 6 152mm Minimum Wall Mounted Object 4 3 4 Optional False Ceil...

Страница 28: ...out of the gap 121mm Minimum 3 76mm 15 381mm 4 3 4 5 127mm Minimum Minimum Maximum Option 3 Valance A valance may be desired to accentuate or hide the CSS outlet Consider framing option 1 or 2 to uti...

Страница 29: ...Termination Sidewall Clearance 7 1 4 Mantle Clearance 6 Clearance reduced to 0 if installed with CSS activated 12 Non Combustible Facing Zone Combustible facing permitted if installed with CSS activat...

Страница 30: ...A protective hearth is not required but highly recommended for the longevity of sensitive flooring materials in front of the appliance If masonry is to be used prepare the necessary foundation for th...

Страница 31: ...its height Example If the overhang height 8ft 2 4m then the overhang must extend at least 4ft 1 2m past each side of the fireplace opening Fireplace may only utilize the Cool Surface System CSS or an...

Страница 32: ...or available options It is acceptable to install a combustible mantel over top of the non combustible board If you are activating the Cool Surface System the mantel clearances may be reduced Refer to...

Страница 33: ...vent configurations It is recommended for vent lengths that pass through unheated spaces garages attics crawl spaces be insulated to minimize condensation NOTE At least 3 76mm of clearance is required...

Страница 34: ...nt lengths that pass through unheated spaces garages attics crawl spaces be insulated to minimize condensation NOTE At least 3 76mm of clearance is required above vent when passing through an exterior...

Страница 35: ...of combustible material Mantel It is not necessary to install a mantel but if one is desired the guidelines as shown in Initial Installation Mantel Requirements Floor The unit must be raised to accom...

Страница 36: ...ine the minimum allowable mantel depth Recess Mantel Installation Always maintain minimum clearances see Figure 60 The total depth of the TV and wall mount as well as the recess depth will determine t...

Страница 37: ...ter line extended above me ter regulator assembly I 3 ft 91 cm 3 ft 91 cm Radial clearance around service regulator vent outlet Table 2 Vent Termination Clearances Vent Termination Restrictions WARNIN...

Страница 38: ...mbustible materials are directly above the first 90 elbow 5 127 mm of clearance is necessary Vertical Pipe to the Side Walls Horizontal Pipe to the Sides Bottom Above First Elbow Above Subsequent Elbo...

Страница 39: ...ved venting parts table Termination Heat Deflector required for all 5x8 installations supplied The following termination restrictions only apply to 5 x 8 venting configurations These restrictions are...

Страница 40: ...1 Vent Part Numbers Town Country Metal Fab Sure Seal Description Metal Fab Urbana 8DV6 6 pipe length TCVT 811X12 8DV12 50 4110 12 pipe length TCVT 811X18 18 pipe length TCVT 811X24 8DV24 50 4108 24 pi...

Страница 41: ...S DVA BVS VSS 5DT VS VSK 5DHVS DVSK 5DVS Vinyl siding standoff sheild 58DVA WT3 58DVA WTU3 5WT 5DT WT 5DWT 5DWT 5DWT11 Wall thimble 58DVA SC SQSC SC 5DT SC 5DSC 5DSC Storm collar 58DVA WFS 5DT FS 5DFS...

Страница 42: ...zontal run for each 45 elbow 1 feet 45 7cm must be subtracted Restrictor Setting Find the point on the graph where your vent configuration will terminate Remember to consider elbows in the HORIZONTAL...

Страница 43: ...is manual for restrictor details Your climate and altitude may alter what restrictor is required for your particular application Figure 65 5 x 8 LP Vent Graph Vertical vent height does not account for...

Страница 44: ...ther vertical or horizontal terminations Any layout within the shaded area is acceptable Note Be sure to use the proper diagram depending on if your unit uses Natural Gas Figure 66 or Propane Figure 6...

Страница 45: ...Figure 68 The proper setting is crucial for an efficient burn and best possible flame appearance It may be necessary to deviate from the recommended setting as different altitudes and climates can var...

Страница 46: ...yl siding For installations using 5x8 venting a vinyl standoff is mandatory for all combustible building exterior finishes See page 40 for more information 5 Horizontal pipes must be supported every 3...

Страница 47: ...Do not pack air spaces with insulation Step 2 Set the appliance in the desired location Drop a plumb bob down from the ceiling to the appliance flue exit and mark the location where the vent will pen...

Страница 48: ...9 Over 20 12 to 21 12 8 2 44 Figure 72 Height of Vertical Termination Reference Table 9 45 elbows x2 Wall strap Plumber s tape connected to wal strap Figure 73 Multi Story Vent Pipe Installation NOTES...

Страница 49: ...m by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soa...

Страница 50: ...receptacle wiring CAUTION When servicing controls label all wires prior to disconnection Wiring errors can cause improper and dangerous operation Verify proper operation after servicing If any of the...

Страница 51: ...the upper and lower rear liners Step 5 Prepare new liners for installation Wear clean vinyl gloves when handling the liners the ceramic material can irritate your skin Take care not to damage the lin...

Страница 52: ...please contact your Urbana dealer for replacement LOG 1 LOG 2 LOG 3 LOG 4 LOG 5 LOG 6 LOG 7 LOG 8 LOG 9 STEP 1 STEP 2 Figure 79 Log Set Installation Step 1 Figure 80 Log Set Installation Step 2 Media...

Страница 53: ...et Installation Step 3 STEP 4 Figure 82 Log Set Installation Step 4 STEP 5 Figure 83 Log Set Installation Step 5 STEP 6 Figure 84 Log Set Installation Step 6 STEP 7 Figure 85 Log Set Installation Step...

Страница 54: ...54 Secondary Installation Figure 87 Log Set Installation Step 9 STEP 9 Figure 88 Correct Log Setup Flame Birch log set shown www tinyurl com 2p8kftpf...

Страница 55: ...on the valve and pilot burner assembly orifice Pilot will not remain lit 7 Day Shutdown The pilot has been in operation for 7 continuous days without main burner operation Turn fireplace ON to reset...

Страница 56: ...ith manual Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started...

Страница 57: ...e 50 4205 Valve Access Panel Gasket 50 4204 15 Firebox Door Roller Set 2pcs 50 4220 16 Firebox Door Spring Relief Assembly 50 4221 17 Firebox Door Handle Set 4pcs 50 4223 18 Valve Pressure Test Port 5...

Страница 58: ...58 Parts Diagram 2 1 13 12 6 5 8 7 3 4 11 10 16 21 25 20 9 14 17 22 18 23 24 15 19...

Страница 59: ...of original purchase must be provided by you or the dealer including serial number Exclusions An expanded list of exclusions is available at www urbanafireplaces com warranty html This warranty does n...

Страница 60: ...__________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in wc MAIN BURNER ORIFICE __________ DMS PILOT...

Отзывы: