17
Figure 5-18
Authentication Scene Interface
Parameter
Description
Authentication
Scene
Temperature
Measurement Only
The visual intercom face recognition terminal only measures people's
temperatures and does not conduct other authentication. For the prompt on
the GUI, see
Note: In this scene, the authentication modes of all libraries configured in the
visual intercom face recognition terminal will be cleared.
Face Scan + Temperature
Measurement
A person is allowed to pass only after the face authentication succeeds and
the temperature is normal. For the prompt on the GUI, see
Face Authenti
Temperature
Measurement
The face whitelist mode + temperature measurement mode are adopted.
A person (whose information is stored in the library) is allowed to pass only
after the face authentication succeeds and the temperature is normal. For the
prompt on the GUI, see
Mask detection and temperature measurement
Note: This scene can be configured only when the default employee library
exists under
Face library management
.
Mask Detection
Enable or disable it based on actual conditions.
Temperature
Configuration
Temperature Unit
The options are as follows:
℃
℉
Set this parameter based on actual conditions.
Temperature
Measurement Range
Value range: [30–45]; default range: [35.5–42]
Configure the range based on actual conditions.
Temperature Alarm
Threshold
When a temperature over the threshold configured here, the terminal will
display a message “abnormal temperature” on the screen and play this