37
Parameter
RS485_1
RS232_1
Flow Control
Stop Bits: 1
Parity: None
Flow Control: None
NOTE!
The parameters cannot be set when
Port Mode
is set to
IC Card Mode
.
Enable Trans-
Channel
It is used for internal debugging. Ignore it.
(2)
Configure serial port information based on actual scene configuration.
(3)
Click
Save
to complete the serial port configuration.
7B.
Wiegand Interface
When the face recognition terminal connects to an IC card reader, Wiegand interface information needs to be
configured. Perform the following operations to complete the configuration:
(1)
Choose
Setup
>
Common
>
Ports & Devices
and click the
Wiegand Interface
tab.
NOTE!
Some devices support the input through only one or zero Wiegand interfaces and the configuration
window for the Wiegand input interface is different for the devices.
Some devices do not support the output through the Wiegand interface. In this case, the configuration
window for the Wiegand output interface will not be displayed.
The Wiegand interface configuration window is unavailable to OET-213H with a built-in IC card reader.
Figure 7-23
Wiegand Interface Configuration Window
(2)
Configure Wiegand interface information by referring to the table below.
Table 7-10
Parameter Description
Parameter
Description
Protocol
Set it based on actual scenes.
Wiegand 26
Wiegand 32
Wiegand 34
Wiegand 36
Wiegand 37
Wiegand 50
Format
The default value is
Ascending Order
. Set this parameter based on actual scenes.
The parameter description is the same as
Format
.
(3)
Click
Save
to complete the Wiegand interface configuration.