39
Parameter
Description
each time the unlock signal is received, and the door opening duration of the door lock will be re-
timed.
Value range: [0–300]s; Default value: 0s
Door Opening Timeout
After
Auto Door Lock Upon Closing
is enabled, if the door closing time exceeds the value here and
the door magnet detects that the door is in the closed position, the face recognition terminal
automatically locks the door.
Value range: [1–300]s; Default value: 10s
NOTE!
It is not recommended to set it to a very small value. Otherwise, normal door opening will be
affected.
The generation of a door magnet alarm is related to door opening timeout.
Auto Door Lock Upon
Closing
Select whether to enable auto door lock upon door closing.
On: When the door magnet detects that the door is closed and the door closing time exceeds
the value of
Door Opening Timeout
, the door will be locked automatically.
Off: The auto door lock upon closing is disabled and the door closing time is the door opening
duration.
Check Door Magnet Status
Before Closing
On: The door magnet status is checked before closing.
Off: The door magnet status is not checked before closing.
(3)
Click
Save
to complete the IO port configuration.
7D.
Volume Control
If the face recognition terminal connects to an audio device, configure audio information on the
Volume Control
tab page.
(1)
Choose
Setup
>
Common
>
Ports & Devices
and click the
Volume Control
tab.
Figure 7-25
Audio Configuration Interface
(2)
Set whether to mute the audio. If no, set the play volume.
(3)
Click
Save
to complete the audio configuration.
7E.
Illumination
The face recognition terminal supports light energy conservation configuration.
(1)
Choose
Setup
>
Common
>
Ports & Devices
and click the
Illumination
tab.
(2)
Set energy conservation parameters based on actual requirements.