background image

-

19

-

Parts List

In order to maintain warranty, components must be replaced using original manufacturers parts purchased 

through your dealer or directly from the appliance manufacturer. Use of third party components will void the 

warranty.

Key Part No. Description

Qty.

1

25507

Feed Door

1

2

25492

Handle, Door

1

3

83506

3/8 x 1 1/4 Roll Pin

1

4

891053

Door Glass

1

5

88066

5/8” Rope Gasket

4.5 ft

6

88087

Glass Gasket (1 x 1 3/16)

3.5 ft

7

25520

Bottom Glass Retainer

1

8

25521

Top Glass Retainer

1

9

83278

Washer

4

10

83202

Machine Screw

4

11

891135

Spring Handle

1

12

25393

Retainer, Glass

1

N/S

25080MB

Door Latch

1

N/S - Not Shown

Key Part No. Description

Qty.

1

69524

Feed Door Assembly

1

2

891372

Door Hinge Pad

2

3

25080B

Feed Door Latch

1

4

69693

Burnpot Housing Weldment

1

5

86624

Burnpot Assembly

1

6

25513

Ash Cleanout

2

7

69713MB

Top/Lid Weldment

1

8

891148

Plastic Handle

1

9

69515MB

Cabinet Side - Left

1

10

80778

Assy, Circuit Board (4-Digit) IR 

Compatible

1

11

25488MB

Cabinet Side - Right

1

12

69787

Hopper Assembly

1

13

80491

MIcroswitch

1

14

83541

#4-40 Bolt

2

15

83542

#4-40 Lock Nut

2

16

25480MB

Access Panel

1

17

80461

Power Supply Cord

1

18

80462

Receptacle, 3 Prong

1

19

891164

Auger Housing Weldment

1

20

891141

Auger

1

21

891189

Top Bushing Plate

1

22

891132

Bushing

1

23

83534

Retaining Ring

1

24

69719

Auger Cover

1

25

891161

Bottom Plate Retainer

1

26

25495

Drive Motor Bracket

1

27

891169

Heater Hose

2

28

80488

Auger Motor

1

29

83529

Hair Pin

1

30

69763

Exhaust Duct Weldment

1

31

88117

Exhaust Duct Gasket

1

32

80473

Exhaust Blower

1

33

88100

Exhaust Blower Gasket

1

34

80480

Thermistor

1

35

86633

Ignitor Tube Weldment

1

36

80619

Ignitor Cartridge

1

37

88118

Ignitor Flange Gasket

1

38

80472

Distribution Blower

1

39

88106

Distribution Blower Gasket

1

40

25774

Pressure Switch Bracket

1

41

80549

Pressure Switch

1

42

89586

Nipple

1

43

891121

Silicone Hose

3”

44

83537

Hose Clamp (#4)

1

45

88119

Insulation Blanket

1

46

88168

Burnpot Housing Gasket

1

47

26096MB

Hearth

1

48

26097MB Grill Mount - Left

1

49

26098MB Grill Mount - Right

1

50

69791MB Louver/Grill Assembly

1

N/S 80780

IR Remote

1

N/S

80779

Digital Wall Thermostat

1

N/S

80798

IR Sensor, Onboard

1

N/S

80548

Main Wiring Harness

1

N/S

80493

Wiring Harness (Microswitch)

1

N/S

891673

Bushing Rtnr. Plate Assy.

1

N/S

25863

Manual Fuel Regulator

1

N/S

83249

Wing Nut

1

N/S - Not Shown

Содержание ASHLEY AP130

Страница 1: ...URE REFERENCE United States Stove Company 227 Industrial Park Road South Pittsburg TN 37380 Please read this entire manual before installation and use of this appliance Failure to follow these instruc...

Страница 2: ...The closed container of ashes should be placed on a non combustible surface or on the ground well away from all combustible materials pending final disposal The exhaust system should be checked monthl...

Страница 3: ...no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdust h...

Страница 4: ...an NFI certified specialist IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper venting or installation Call 800 750 272...

Страница 5: ...m CORNER D Adjacent wall to unit 8 00 203mm ALCOVE E Alcove depth 36 00 914mm 5500 M only F Alcove height 60 00 520mm CLEARANCES Your pellet stove has been tested and listed for installation in reside...

Страница 6: ...the stove use a 3 inch to 4 inch adapter for 4 inch pipe Connection at back of stove must be sealed using Hi Temp RTV Use 4 inch vent if the vent height is over 12 feet or if the installation is over...

Страница 7: ...ith a kit that will handle most of this installation which will include a wall thimble that will allow the proper clearance through a combustible wall Once outside the structure a 3 in 76mm clearance...

Страница 8: ...g of the detector when reloading In addition to the previously detailed installation requirements mobile home installations must meet the following requirements The heater must be permanently bolted t...

Страница 9: ...er of this manual Because a forced draft pressure is required for the combustion process inside your stove it is extremely important that the exhaust system be properly installed and maintained And th...

Страница 10: ...at will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fa...

Страница 11: ...the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Sta...

Страница 12: ...4 Auger Output Test The display will show augr The auger motor is turned on full If the Auger Fuse is not blown and the fuse detection circuit is functioning the Heat Range LED will be lit and the ot...

Страница 13: ...urely closed the safety pressure switch will not allow the stove to feed fuel if there is no draft pressure inside the stove 7 Press the ON button on the control pad and set the heat Setting to your d...

Страница 14: ...ON button on the digital control panel your stove will begin to feed fuel and automatically start within 5 minutes TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that mus...

Страница 15: ...this could damage the glass DO NOT abuse the door glass by striking slamming or similar trauma Do not operate the stove with the glass removed cracked or broken FALL START UP Prior to starting the fir...

Страница 16: ...s down Hopper is empty refill the hopper Loss of draft pressure Make sure that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outsid...

Страница 17: ...g the lighting stage Quickly changes twice per second Flashing Heat Range Setting Indicator This indicates that the stove is in normal operation and that an over temperature condition exists causing t...

Страница 18: ...18 GRAY BLACK Wiring Diagram CORRECT WRONG Insure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 19: ...40 Lock Nut 2 16 25480MB Access Panel 1 17 80461 Power Supply Cord 1 18 80462 Receptacle 3 Prong 1 19 891164 Auger Housing Weldment 1 20 891141 Auger 1 21 891189 Top Bushing Plate 1 22 891132 Bushing...

Страница 20: ...20 11 3 2 1 5 6 4 7 9 8 10 12 Parts Diagram 47 46 48 49...

Страница 21: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 22: ...s pi ces d tach es Gardez ce manuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fi...

Страница 23: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 24: ...2 15 83542 4 40 crou 2 16 25480MB Panneau D acc s 1 17 80461 Cordon D alimentation 1 18 80462 R ceptacle 3 Prong 1 19 891164 Auger Logement Weldment 1 20 891141 Vrille 1 21 891189 Top Bushing Plate 1...

Страница 25: ...20 Sch ma des pi ces 11 3 2 1 5 6 4 7 9 8 10 12 47 46 48 49...

Страница 26: ...SOSTAT MARRON MARRON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCIPAL NOIR NOIR NOIR BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR Sch ma de c blage...

Страница 27: ...Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur Heat Range clignotant...

Страница 28: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Страница 29: ...le et d paisseur correctes doivent tre utilis es NE substituez PAS le verre avec des mat riaux alternatifs Contactez votre revendeur autoris pour obtenir ce verre R installez le nouveau verre en le fi...

Страница 30: ...fi peut effectuer ces travaux Il est aussi recommand qu avant chaque saison de chauffage le syst me complet soit inspect nettoy et si n cessaire r par par un professionnel Pour nettoyer la chemin e d...

Страница 31: ...sur le bouton OFF arr t et ensuite de nouveau sur le bouton ON marche pour commencer une nouvelle s quence de mise en route 2 Si le po le a refroidi il se r initialisera l tat OFF arr t ce moment l vo...

Страница 32: ...de l eau sal e 11 Bois non s ch ou 12 Produits du papier carton contreplaqu ou panneau de particules L interdiction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de pa...

Страница 33: ...fin se met en marche plein r gime Si le fusible de la vis sans fin n a pas saut et que le circuit de d tection fusible fonctionne le voyant DEL Heat Range du degr de chaleur sera allum et les trois au...

Страница 34: ...justez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE L...

Страница 35: ...rage forc e est n cessaire au processus de combustion l int rieur de votre po le il est extr mement important que le syst me d vacuation soit install correctement et maintenu Et que lors du fonctionne...

Страница 36: ...ionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le...

Страница 37: ...s parois et du plafond toit de la maison mobile doit tre maintenue Un d tecteur de fum e fonctionnel doit tre install dans la m me pi ce que ce produit Il doit tre install au moins 15 pieds 4 57 m de...

Страница 38: ...rd en T de regard devra tre plac sur le tuyau avec une sortie 90 degr s hors de la maison ce point une partie de tuyau de 3 pieds 0 91m minimum devra tre ajout e avec un couvercle horizontal qui devra...

Страница 39: ...e doit tre scell en utilisant un produit vulcanis RTV pour temp ratures lev es Utilisez une ventilation de 4 pouces si la hauteur de ventilation est sup rieure 12 pieds ou si l installation se trouve...

Страница 40: ...re minimum plus grand afin d obtenir un acc s commode au panneau de contr le FIGURE 3 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION EN PARALL LE FIGURE 4 D GAGEMENTS DE LA PAROI LAT RALE INSTALLATION...

Страница 41: ...cialiste certifi NFI NE CONNECTEZ PAS CETTE UNIT UN CONDUIT OU CIRCUIT DE DISTRIBUTION D AIR INSTALLATION INCORRECTE Le fabricant ne sera pas tenu responsable des dommages caus s par un dysfonctionnem...

Страница 42: ...ar pied cube diam tre de 1 4 5 16 po longueur non sup rieure 1 5 moins de 8 200 BTU lb humidit inf rieure 8 en poids cendres inf rieure 1 en poids et sel inf rieur 300 parties par million Les granul s...

Страница 43: ...d entretien ou de nettoyage Les cendres doivent tre jet es dans un conteneur m tallique avec un couvercle d ajustement serr Le conteneur ferm dans lequel se trouvent les cendres devra tre plac sur un...

Страница 44: ...d un permis de construire Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agency Certifi aux normes d missions de 2015 particules United...

Отзывы: